HEARTH PRODUCTS KITS AND ACCESSORIES
750,216M
REV. N/C 03/2006
BLOWER KIT LBLK-100
INSTALLATION INSTRUCTIONS FOR BLOWER KIT
LBLK-100 (CATALOG NO. H4678) FOR USE WITH ELDV SERIES FIREPLACES
GENERAL INFORMATION
This blower kit may be used with ELDV series fireplaces. The LBLK- 100 blower kit is used with a field supplied ON/OFF power switch. The blower is installed beneath the firebox. Room air is drawn in through the bottom area of the fireplace, heated as it passes across the firebox, and discharged through the upper open area at the top of the fireplace. The
INSTALLATION INSTRUCTIONS
Step 1. Turn off the fireplace and allow it to cool before proceeding.
Step 2. If the appliance is connected to 120 volt power, disconnect the power.
Step 3. Shut off the gas supply to the fireplace.
Step 4. Remove the bottom panel of the fireplace by pulling it forward. (see Figure 1 ).
Step 5. Remove the door assembly by opening the two latches (located under the door assembly) securing the glass door (see Figure 1 ).
Logs | Door Asembly |
Step 6. Remove the logs from the fireplace (see Figure 1 ). Handle logs carefully to prevent breakage.
Step 7. Remove the grate asembly, burner baffle, burner asembly (Figure 2 ) and the blower cover panel (Figure 3 ).
Step 8. Connect the provided power cord to the terminals on the blower.
Blower Cover Panel | Burner Assembly |
Grate Assembly | Burner Baffle |
Figure 2
Blower Cover Panel
| Bottom Panel |
Figure 1 | Figure 3 |
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.