WARNING
Carbon monoxide poisoning: early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtainfreshairimmediately.Turn off the gas supply to the appliance and have it serviced by a quali- fied professional, as it may not be operating correctly.
WARNING
Children and adults should be alerted to the hazards of high surface temperatures. Use cau- tion around the appliance to avoid burns or clothing ignition.
|
| Note:The gas supply | ||
|
| line must be installed | ||
|
| in accordance with | ||
|
|
| building codes by a | |
|
|
| qualified installer | |
|
|
| approved and/or | |
|
|
| licensed as requed | |
|
|
| by the locality. In | |
| OFF/PILOT/ON (gas control knob) | the Commonwealth | ||
HI/LO (flame height |
|
| of Massachusetts, | |
|
| installation must | ||
control knob) |
|
|
| |
|
|
| be performed | |
|
|
|
| |
|
|
|
| by a licensed |
OFF/ON Switch |
| Gas Flex Line | plumber or gas | |
|
|
| fitter. | |
Hinge Pin |
|
|
| |
|
|
|
| |
|
| Gas Valve | ||
Control | Piezo Igniter |
|
| |
|
|
|
| |
Compartment Access panel |
|
| ||
Figure 1 - Gas Control Compartment Access |
|
|
| |
OPERATION AND CARE OF YOUR |
| SIT Millivolt | Gas Valve | |
APPLIANCE |
| |||
| HI/LO Variable |
|
| |
|
|
| Inlet Pressure Tap | |
The standard controls for appliance operation | Flame Height |
| ||
Adjustment |
|
| ||
are located behind the hinged |
|
| ||
Manifold Pressure Tap |
Youngchildrenshouldbecarefully supervised when they are in the same room as the appliance.
Note: An Optional Screen Heat Guard for the glass is available (see Page 14 for ordering infor- mation).
below the appliance front glass enclosure panel (see Figure 1). Optional control switches are also available (see Page 12 - Remote Wall
Switch, Remote Control or Wall Thermostat).
Operation of millivolt and electronic gas con- trol systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance. Familiarize yourself with the gas control valve that your appliance uses. Refer to Figure 1 for access
|
|
| OUT | IN |
TPTH |
|
|
|
|
T |
| I H |
|
|
P |
|
| OFF |
|
|
|
| P | |
|
|
|
| |
|
|
|
| I |
|
| LO W | it | L |
TH |
| O | ||
|
|
| NO | T |
|
|
|
| |
|
| P |
|
|
| I |
|
| |
| TOL |
|
|
|
Pilot Adjustment | Main Gas |
Screw | Control Knob |
| OFF/PILOT/ON |
WARNING
Any safety guard or screen removed for servicing the appli- ance must be replaced prior to operating the appliance.
Gas Control Compartment Access
The gas controls can be found behind the control compartment access panel.
To open the control compartment access panel,
to the gas control valve.
Millivolt Appliances - Appliances with Millivolt systems will be fitted with the gas control valve shown in Figure 2.
Electronic Appliances - Appliances with electronic systems will be fitted with the electronic valve shown in Figure 3.
Millivolt Appliances -
To light millivolt appliances refer to the detailed lighting instructions found on Page 15 . Millivolt appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.
Gas
Outlet
Terminals
TPTH,TP & TH
|
|
|
|
| OFF | ON |
|
|
|
|
|
|
|
|
|
Gas
Inlet
TPTH |
|
TP |
|
TH |
|
HI/LO Variable | Main Gas |
Flame Height | Control Knob |
Adjustment | OFF/PILOT/ON |
OFF/ONIGNITER (burner)
4
actuate the
On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/ON control knob are located below the glass panel enclosure. The gas valve for electronic systems is also located below the glass enclosure panel. See Figure 1.
To ease door closure, depress the catches to place them in their retracted position, then close the door.
Millivolt appliances are fitted with an OFF/ON Rocker Switch located behind the control compartment access panel, below the appli- ance front glass enclosure panel (see Figure 1 for location). Once the pilot is lit, the OFF/ON rocker switch will control the appliance OFF/ON burner operation. To operate: Toggle the switch between its ON and OFF positions.
If your millivolt appliance is equipped with an optional remote switch kit (wall switch, remote control or wall thermostat) and the pilot is lit, the appliance main burner may be turned on and off using the optional switch. When using an optional remote switch, turn off the standard OFF/ON switch.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
| Note: The piezo igniter and burner |
| OFF/ON switch are located below |
Figure 2 | glass panel (see Figure 1). |
Note: To prevent excessive resistance in burner circuit (which can cause burner operation prob- lems), only one burner control switch should be wired to valve. Therefore, if an optional control switch is installed, the standard Off/On switch and wires should be removed.
Electronic Appliances -
To light electronic appliances refer to the detailed lighting instructions found on Page 16. Elec- tronicappliancelightinginstructionsmayalsobe found on the pull out lighting instruction labels attached to the gas control valve.