LENNOX HEAT PUMP ACCESSORIES

LENNOX HEAT PUMP ACCESSORIES

,1,_2003 Lennox industries Inc,

TeOh nical blications

Litho U.S.A.

Dallas, Texas, USA

504,797M

 

05/03

HEAT PUMP CONTROL

T-STAT DF TEMPER KIT

INSTALLATION INSTRUCTIONS FOR T-STAT DF TEMPER KIT (#67M41) FOR USE

WITH LENNOX DUAL FUEL/BALANCE POINT CAPABLE THERMOSTATS

Package 1 of 1 contains the following: 1 - DT1 Discharge thermostat probe

1 - Bag assembly containing:

2 - wire nuts

4- #8-18 x 1/2 screws Field-provided supplies:

Thermostat wire

DT1 Discharge Temperature Probe

Installation Location

evaporator coil

DT1

discharge thermostat

probe

The DT1 defrost discharge thermostat is designed to be used with Lennox thermostats that have dual fuel capa- bilities and setable balance points, The thermostat al- lows for the furnace to cycle on and off during a defrost in order to temper the discharge air, and it protects the compressor from high refrigeration pressures during de- frost,

Installing the DT1 Discharge Thermostat Probe

The DT1 discharge thermostat probe must be installed between the indoor coil and the furnace,

1 - Find a location to install the probe that is on the the coil endplate, Ensure that the probe will clear all plumbing.

2- Remove the endplate from coil and cut a hole approximately 2" in diameter to allow for the DT1, 3 - With airflow arrow pointing in the appropriate posi- tion, use the four provided screws to secure the

probe to the endplate,

4 - Replace the endplate to the coil,

5- Using field-provided thermostat wire, connect the DT1 ($89) to the W1 terminal of the defrost board and W1 terminal of the furnace, See figure 2,

DT1 must be installed between the furnace and the evaporator coil with airflow arrow in correct position. Upflow application shown.

Figure 1

DT1 Discharge Temperature Probe Wiring

W1

 

W1

0

o%0

0

Defrost

DT1 (589) Discharge Air Sensor

Furnace

Board

80°F close

 

90°F open

Locate sensor in the air stream between

the furnace and the coil.

Figure 2

05/03

 

504,797M