6 - White Rodgers 36E Gas Valve - Switch gas valve lever to OFF. See figure 2.
Honeywell VR8205 Gas Valve - Turn knob on gas valve
clockwise to OFF. Do not force. See figure 3.
WHITE RODGERS 36E SERIES GAS VALVE
GAS VALVE SHOWN IN OFF POSITION
FIGURE 2
HONEYWELL VR8205 SERIES GAS VALVE
ON
OFF
GAS VALVE SHOWN IN OFF POSITION
FIGURE 3
7 - Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you do not smell gas go to next step.
8 - White Rodgers 36E Gas Valve - Switch gas valve lever to ON.
Honeywell VR8205 Gas Valve - Turn knob on gas
valve counterclockwise to ON. Do not force.
9 - Replace the control access panel.
10 - Turn on all electrical power to unit.
11 - Set thermostat to desired setting.
NOTE – When unit is initially started, steps 1 through 11 may need to be repeated to purge air from gas line.
12 - If the appliance still will not operate, follow the instructions •To Turn Off Gas To Unit" and call your service technician or gas supplier.
To Turn Off Gas To Unit
1 - Set thermostat to lowest setting.
2 - Turn off all electrical power to unit if service is to be performed.
3 - Remove the control access panel.
4 - Switch lever on White Rodgers gas valve to OFF; turn knob on Honeywell valve clockwise to OFF. Do not force.
5 - Replace the control access panel.
Filters
80UHG series units are equipped with external filters which should be inspected monthly and replaced when necessary to assure proper furnace operation. See table 1 for filter sizes. Replacement filters used with
| TABLE 1 | |
|
| |
MODEL NUMBER | FILTER SIZE | |
| ||
1 FILTER | ||
| ||
|
| |
|
| |
16 in. X 20 in. X 1 in. | ||
|
| |
20 in. X 20 in. X 1 in. | ||
|
|
UPFLOW FURNACE
BOTTOM RETURN AIR
FIGURE 4
Page 4