Lennox International Inc F8AUH manual Important Directions

Models: F8AUH

1 6
Download 6 pages 31.43 Kb
Page 2
Image 2
Important Directions

PARTS IDENTIFICATION

 

 

4

 

 

1

 

 

2

1

- COMBUSTION AIR

 

 

 

 

BLOWER

5

2

- PRESSURE SWITCH

 

3

- BURNERS

 

4

- HEAT EXCHANGER

 

5

- GAS VALVE

3

6

- CONTROL BOARD

 

7

- BLOWER

6

 

 

7

 

 

Manual backgroundWARNING

Product contains fiberglass wool.Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiber4 glass wool. Breathing this may cause lung can4 cer. (Fiberglass wool is known to the State of California to cause cancer.)Fiberglass wool may also cause respiratory, skin, and eye irritation.To reduce exposure to this substance or for further information, consult material safety data sheets available from address shown below, or contact your supervisor

P.O. Box 799900 Dallas, TX 75379-9900

Manual backgroundWARNING

If overheating occurs or if gas supply fails to shut off, shut off the manual gas valve to the appliance before shutting off electrical supply.

Manual backgroundWARNING

Do not use this furnace if any part has been under4 water. Immediately call a qualified service techni4 cian to inspect the furnace and to replace any part of the control system and any gas control which has been under water.

Manual backgroundCAUTION

Before attempting to perform any service or mainte4 nance, turn the electrical power to unit OFF at dis4 connect switch.

Manual backgroundIMPORTANT

Any additions, changes, or conversions required in order for the appliance to satisfactorily meet the ap4 plication needs must be made by a qualified service technician using factory specified and approved parts.

Important Directions

1 - Keep the furnace area clear and free of combustible material, gasoline, and other flammable vapors and liq6 uids. If installed in an insulated area, furnace must be kept free of insulating material. Insulating material may be combustible. Inspect furnace venting system to make sure it is in place, physically sound, and without holes, corrosion, or blockage. Inspect furnace return air duct connection to ensure duct is sealed to the fur6 nace and terminates outside the space containing the furnace. Inspect the physical support of the furnace to guarantee that it is sound without sagging, cracks or gaps around base and it maintains seal between base and support.

2

Page 2
Image 2
Lennox International Inc F8AUH manual Important Directions