CAUTION

Do not set thermostat below 60°F (16°C) in heating mode. Setting thermostat below 60°F (16°C) reduces the number of heating cycles. Damage to the unit may occur that is not covered by the warranty.

WARNING

If overheating occurs or if gas supply fails to shut off, shut off the manual gas valve to the furnace before shutting off electrical supply.

WARNING

Do not use this furnace if any part has been underwa- ter. A flood−damaged furnace is extremely danger- ous. Attempts to use the furnace can result in fire or explosion. Immediately call a licensed professional service technician (or equivalent) to inspect the fur- nace and to replace all gas controls, control system parts, and electrical parts that have been wet or to re- place the furnace, if deemed necessary.

NOTICE

Any additions, changes, or conversions required in order for the appliance to satisfactorily meet the ap- plication needs must be made by a licensed profes- sional installer (or equivalent) using factory−speci- fied and approved parts.

WARNING

Improper installation, adjustment, alteration, service or maintenance can cause property damage, person- al injury or loss of life. Installation and service must be performed by a licensed professional installer (or equivalent), a service agency, or the gas supplier.

Safety Instructions

1 − Keep the furnace area clear and free of combustible material, gasoline, and other flammable vapors and liquids. If it is installed in an insulated area, the furnace must be kept free of insulating material. Insulating ma- terial may be combustible.

2 − After any heavy snow, ice or frozen fog event, the fur- nace vent pipes may become restricted. Always check the vent system and remove any snow or ice that may be obstructing the plastic intake or exhaust pipes.

3 − DO NOT obstruct air flow to unit. Unit must receive an unobstructed flow of combustion and ventilating air. DO NOT block or obstruct air openings on the furnace or air openings to the area in which the furnace is

installed. Take care to maintain established clear- ances surrounding the furnace.

4 − DO NOT store chlorine or fluorine products near unit or introduce these products into the combustion air. These products can cause furnace corrosion.

5 − DO NOT draw return air from a room where this fur- nace, or any other gas appliance (ie., a water heat- er), is installed. When return air is drawn from a room, a negative pressure is created in the room. If a gas ap- pliance is operating in a room with negative pressure, the flue products can be pulled back down the vent pipe and into the room. This reverse flow of the flue gas may result in incomplete combustion and the formation of carbon monoxide gas. This toxic gas might then be distributed throughout the house by the furnace duct system.

WARNING

The blower door must be securely in place when the blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into the living space resulting in personal injury or death.

Your furnace is a gas appliance. It is critical that the gas

supplied to the unit be completely burned to avoid the pro- duction of carbon monoxide gas. Complete combustion of the gas requires, but is not limited to, correct gas pressure and gas flow rate, adequate combustion, air, and proper venting.

WARNING

Carbon monoxide gas is invisible, odorless and tox- ic.

Exposure to carbon monoxide gas can cause personal in-

jury and even death to all occupants, including pets. Any

item that is powered by or gives off heat from a combustion

process (including lawn mowers, automobiles, and fire- places) has the potential to produce carbon monoxide gas.

Because of this, Lennox recommends the use of a car- bon monoxide detector in your home, even if you do

not own gas appliances. Reliable detectors are available at reasonable retail prices. Contact your Lennox dealer for more details about this investment in your safety.

Your furnace is designed to meet standards set by national agencies, and to operate safely when properly installed and maintained. However, the unit’s performance can be greatly impacted by the individual installation and the oper-

ating environment. It is your responsibility to ensure that this appliance is maintained.

Proper maintenance is critical for your safety and the satis- factory operation of the product. Lennox strongly recom-

mends annual inspection and maintenance of this ap-

pliance. Contact your Lennox dealer for an inspection by a

licensed professional service technician.

Page 3

Page 3
Image 3
Lennox International Inc G71MPP manual Safety Instructions, Carbon monoxide gas is invisible, odorless and tox- ic

G71MPP specifications

Lennox International Inc. has long been recognized as a leader in the HVAC industry, and one of its notable offerings is the G71MPP gas furnace. This high-efficiency unit reflects the company’s commitment to innovation, performance, and sustainability. The G71MPP is designed to provide exceptional comfort with a focus on energy efficiency and advanced technology.

One of the main features of the G71MPP is its impressive Annual Fuel Utilization Efficiency (AFUE) rating, reaching up to 97%. This means that a significant percentage of the energy consumed is converted into heat, leading to lower utility bills and reduced environmental impact. With such high efficiency, homeowners can enjoy warmth without the guilt of excessive energy consumption.

The G71MPP features a modulating gas valve, which allows for precise temperature control. This technology enables the furnace to adjust its heating output to match the specific needs of the home at any given time. As a result, it provides a consistent, comfortable indoor environment while minimizing energy usage. The unit also showcases a variable-speed blower motor, which improves airflow efficiency and enhances indoor air quality by reducing the circulation of dust and allergens.

For even greater control and convenience, Lennox integrates its Smart Thermostat technology with the G71MPP. This feature allows users to program their heating schedules via a smartphone app, ensuring that their home is always at the ideal temperature when they arrive. Additionally, the unit is compatible with home automation systems, making it easier than ever to manage home comfort.

Durability is a hallmark of the G71MPP, as it is constructed with high-quality materials built to withstand the rigors of time and use. The unit features a rugged stainless steel heat exchanger that not only enhances the performance but also extends the lifespan of the furnace. Furthermore, its quiet operation is a significant benefit, ensuring that homeowners can enjoy a cozy environment without the disruptive noise often associated with traditional furnaces.

In conclusion, Lennox International Inc.’s G71MPP gas furnace stands out as a reliable, efficient, and technologically advanced heating solution. With its high AFUE rating, modulating gas valve, variable-speed blower motor, and connectivity features, it embodies the future of home heating. As energy costs continue to rise, the G71MPP offers an effective solution for homeowners seeking comfort, efficiency, and smart technology in their heating systems.