Husqvarna 340, 345, 346XP,350, 351, 353 manual Tensioning the recoil spring, Repair instructions

Models: 340, 345, 346XP,350, 351, 353

1 52
Download 52 pages 42.29 Kb
Page 23
Image 23
Tensioning the recoil spring

Repair instructions

Cleaning and inspection:

Clean and inspect all parts carefully. If there are any cracks or other defects replace the dam- aged parts with new ones. Lubricate the return spring with light oil.

Tensioning the recoil spring

1

Fasten the starter cord in the notch in the pulley rim and wind the pulley about 2 turns clockwise. Check that the pulley is free to rotate at least another half turn when the starter cord is fully extended.

Replacing a worn recoil spring

WARNING!

Make sure the recoil spring does not fly out and cause injury. Wear eye protection.

1

Remove the bolt from the centre of the pulley and lift off the pulley and spring.

2

Remove the broken recoil spring.

3

Fit the bolt through the centre of the pulley and tighten to a torque of 2–3 Nm.

Tension the recoil spring, see “Tensioning the recoil spring”.

Starter assembly – refitting

1

Position the starter assembly on the crankcase and tighten the bolts to a torque of 2.5–3.5 Nm.

22 – English

Page 23
Image 23