Husqvarna 340, 345, 346XP,350, 351, 353 manual Ignition module and flywheel - refitting, 0,3 mm

Models: 340, 345, 346XP,350, 351, 353

1 52
Download 52 pages 42.29 Kb
Page 26
Image 26
Ignition module and flywheel – refitting

Repair instructions

Ignition module and flywheel – refitting

1

Place the flywheel on the crankshaft. Turn the flywheel so that the key lines up with the keyway in the shaft.

Fit the washer and nut on the shaft and tighten to a torque of 25-30 Nm.

2

0,3 mm

To refit the ignition module proceed as follows:

Turn the flywheel so that the magnets are in line with the ignition module. Fit the ignition module with the plastic feeler gauge (502 51 34-01) held in position at the same time, without tightening the bolts. Connect the black earth lead to the front screw on the ignition module. Adjust the gap between the ignition module and magnet to 0.3 +/-

0.1mm. The gap must be measured at either of the two lowest pegs on the ignition module. Tighten the bolts to 4.5–6 Nm. Connect the blue lead to the ignition module.

3

Then refit:

cable guide and press the leads into position

HT lead

starter assembly, tighten to a torque of 2.5–3.5 Nm

cylinder cover

English – 25

Page 26
Image 26
Husqvarna 340, 345, 346XP,350, 351, 353 manual Ignition module and flywheel - refitting, 0,3 mm, Repair instructions