2. Channel Status LEDs

CX Power Amplifiers

Basic Operation

1

2

2. Channel Status LEDs

Provide an at-a-glance view of the status of each channel as indicated in the table below:

 

Color

Status

 

 

 

 

 

 

 

 

 

 

Constant Blue

Normal Operation

 

 

 

 

Note:

 

 

 

 

 

Constant Bright Blue

Indicates the audio signal is clipping. Reduce volume level to help

 

 

 

When the main power transformer temperature

 

 

eliminate potentially damaging audio signals from reaching the speakers.

 

 

 

 

 

exceeds 100˚C:

 

 

The temperature of the individual amplifier heatsink is above 95˚C. If this

 

 

 

 

• the transformer will deactivate

 

Flashing Blue

occurs, the channel will not pass audio. The channel status LED will return

 

 

 

•the channel status LEDs will no longer be lit

 

 

to constant blue when the temperature of the amplifier card returns to

 

 

 

 

•the red standby LED will flash rapidly

 

 

normal. Then the channel will automatically resume passing audio.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All Channels Flashing

The temperature of the chassis is above 58˚C, and the amplifier will no

 

 

 

 

longer pass audio. After the chassis temperature returns to normal, all the

 

 

 

 

Blue

channel status LEDs will return to constant blue and the amplifier will

 

 

 

 

 

resume normal operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

2-3

 

Page 11
Image 11
Lexicon CX-7, CX-5 Channel Status LEDs, Basic Operation, CX Power Amplifiers, When the main power transformer temperature

FAQ

What do the constant blue LEDs indicate?

The constant blue LEDs indicate normal operation of the amplifier.

What does flashing blue LED indicate?

Flashing blue LED indicates that the channel will not pass audio due to high temperature, but will resume normal operation once the temperature returns to normal.

How do I troubleshoot if all channels are flashing blue?

If all channels are flashing blue, it means the chassis temperature is above 58C. Once the chassis temperature returns to normal, all the channel status LEDs will return to constant blue and the amplifier will resume normal operation.