LG Electronics 26CS460/460S/460T-ZA, 26CS460T Total Assembly line process, Function Check

Models: 26CS460/460S/460T-ZA 26CS460T CS26460T-ZA

1 53
Download 53 pages 6.42 Kb
Page 12
Image 12
3.4 Function Check

3.4 Function Check

-Check display and sound

Check Input and Signal items.

1)TV

2)AV (SCART / CVBS)

3)COMPONENT (480i)

4)RGB (PC : 1024 x 768 @ 60hz) (* RGB input : LD21B only support)

5)HDMI

6)PC Audio In (* except LD21A chassis model)

* Display and Sound check is executed by Remote control.

<Caution>

Not to push the INSTOP key after completion if the function inspection.

4. Total Assembly line process

4.1. Adjustment Preparation

W/B Equipment condition CA210

:CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE)

LED -> CH14, Test signal: Inner pattern(80IRE)

If it is executed W/B adjustment in 2~3 minutes H/run, it is adjusted by Target data

Mode

Temp

Coordinate spec

Target

 

Cool

13,000k

X=0.269 (±0.002)

X=0.271

LAMP

Y=0.273 (±0.002)

Y=0.276

<Test Signal>

Medium

9,300k

X=0.285 (±0.002)

X=0.287

Inner pattern

Y=0.293 (±0.002)

Y=0.296

(204gray,

 

 

 

 

 

 

80IRE)

Warm

6,500k

X=0.313 (±0.002)

X=0.315

Y=0.329 (±0.002)

Y=0.332

 

 

 

 

*Connecting picture of the measuring instrument (On Automatic control)

Inside PATTERN is used when W/B is controlled. Connect to auto controller or push Adjustment R/C POWER ON → Enter the mode of White-Balance, the pattern will come out.

Full White Pattern

CA-210

 

 

COLOR

ANALYZER

TYPE : CA-210

RS-232C Communication

*Auto-control interface and directions

(1)Adjust in the place where the influx of light like floodlight around is blocked. (illumination is less than 10 lux).

(2)Adhere closely the Color analyzer(CA210) to the module less than 10 cm distance, keep it with the surface of the Module and Color analyzer's prove vertically.(80° ~ 100°).

(3)Aging time

-After aging start, keep the power on (no suspension of power supply) and heat-run over 5 minutes.

-Using 'no signal' or 'POWER ONLY' or the others, check the back light on.

▪ Auto adjustment Map(using RS-232C to USB cable)

 

RS-232C COMMAND

 

 

 

 

 

 

[CMD ID

DATA]

 

 

 

 

 

 

Wb

00

00

 

White Balance Start

 

 

Wb

00

ff

White Balance End

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C COMMAND

 

 

CENTER

 

 

 

[CMD ID DATA]

 

MIN

 

(DEFAULT)

MAX

 

 

Cool

Mid

 

Warm

 

Cool

Mid

Warm

 

R Gain

 

jg

Ja

 

jd

00

172

 

192

192

192

G Gain

 

jh

Jb

 

je

00

172

 

192

192

192

B Gain

 

ji

Jc

 

jf

00

192

 

192

172

192

R Cut

 

 

 

 

 

 

64

 

64

64

128

G Cut

 

 

 

 

 

 

64

 

64

64

128

B Cut

 

 

 

 

 

 

64

 

64

64

128

<Caution>

Color Temperature : COOL, Medium, Warm.

One of R Gain/G Gain/ B Gain should be kept on 0xC0, and adjust other two lower than C0.(When R/G/B Gain are all C0, it is the FULL Dynamic Range of Module)

*Manual W/B process using adjust Remote control.

After enter Service Mode by pushing "ADJ" key,

Enter White Balance by pushing "►" key at "8. White Balance".

 

EZ ADJUST

White Balance

 

 

 

0. Tool Option1

Color Temp.

Cool

1. Tool Option2

R-Gain

172

2. Tool Option3

G-Gain

172

3. Tool Option4

B-Gain

192

4. Tool Option5

R-Cut

64

5.

Country Group

G-Cut

64

6. Area Option

B-Cut

64

7. ADC Calibration

Test-Pattern

ON

8.

White Balance

Backlight

100

9.

10 Point WB

Reset

To Set

10.Test Pattern

11.EDID D/L

12.Sub B/C

13.Touch Sensitivity Setting

* After you finished all adjustments, Press "In-start" key and compare Tool option and Area option value with its BOM, if it is correctly same then unplug the AC cable. If it is not same, then correct it same with BOM and unplug AC cable. For correct it to the model's module from factory Jig model.

*Push the "IN STOP" key after completing the function inspection. And Mechanical Power Switch must be set “ON”.

Copyright ©

LG Electronics. Inc. All rights reserved.

- 12 -

LGE Internal Use Only

Only for training and service purposes

 

 

Page 12
Image 12
LG Electronics 26CS460/460S/460T-ZA, 26CS460T Total Assembly line process, Function Check, Adjustment Preparation