11. Deflection setting initial data
ITEM | Range | RF PAL |
| RF NTSC | |
|
|
| 1080i/50 | ||
|
| 100Hz | 1080i/50 |
| |
|
|
|
| ||
|
|
|
|
|
|
VL | 0 ~ FFFF | FFFC | FFF3 |
| FFDD |
|
|
|
|
|
|
VA | 0 ~ FFFF | 004E | 0014 |
| 002A |
|
|
|
|
|
|
SC | 0 ~ FFFF | 009E | 009E |
| 007C |
|
|
|
|
|
|
VS | 0 ~ FFFF | FFF8 | FF10 | 0003 | |
|
|
|
|
|
|
HS | 0 ~ FFFF | 005D | 005E |
| 005C |
|
|
|
|
|
|
EW | 0 ~ FFFF | 0044 | 0041 |
| 006C |
|
|
|
|
|
|
ET | 0 ~ FFFF | FFFB | FFDE |
| FFC0 |
|
|
|
|
|
|
EP | 0 ~ FFFF | FFD0 | FEE2 |
| FE94 |
|
|
|
|
|
|
CRNU | 0 ~ FFFF | 0004 | 0004 |
| FFF6 |
|
|
|
|
|
|
CRNL | 0 ~ FFFF | 000B | 0025 |
| 002A |
|
|
|
|
|
|
BOW | 0 ~ FFFF | 000B | 0007 | 0007 | |
|
|
|
|
|
|
ANGLE | 0 ~ FFFF | 000A | 0009 | 0009 | |
|
|
|
|
|
|
CRNU6 | 0 ~ FFFF | 0056 | 003A | 0056 | |
|
|
|
|
|
|
CRNL6 | 0 ~ FFFF | 003F | 0030 | 0042 | |
|
|
|
|
|
|
*Check adjustment condition at 1080i/50Hz, NTSC60Hz after finishing adjustment in PAL100Hz, adjust defection adjustment at each Mode again.
*Sequence
:PAL 100Hz(RF)
12.How to inspect condition of a transmission and reception in wireless sound model(option)
-Wireless sound model’s efficiency inspections is executed to a finished in a final inspection phase.
-Wireless sound is a function which receives
1)Execute in channel generating
2)Select a transmitted frequency in MENU OSD.
3)A received frequency in an exclusive remote control or received FM Radio is tuned by 87.7MHz which is same as frequency in OSD.
4)Check out whether a signal generating to MAIN SPEAKER generates in earphone or receiver or not.
5)There is no alternation and setting of adjusted DATA in the process of inspecting FM TX.
13. OPTION setting
13-2. Preliminary steps
1)This option adjustment decides function in accordance with model. Press the SVC TX adjustment button(CH up/down button) at SVC mode, then adjust the option at OPTION1, 2, 3, 4, 5 mode.
2)Mark the option adjustment data like [111,111,111,111,111] in BOM.
OP [113,63,112,201,248]
OPTION 1
OPTION 2
OPTION 3
OPTION 4
OPTION 5
* Mark of BOM |
|
| |
LEVEL | PART NO. | SPECIFICATION | DESCRIPTION |
1. | 3141VMNxxxA | MAIN CHASSIS ASSY | OPT[091,016,143,100,000] |
In this model, the OPTION1 data is 091, OPTION2 data is 016, the OPTION3 data is 143,the OPTION 4 data is 100, OPTION 5 data is 000.
13-2. Adjustment Method
1)Input OPTION value with number button on remote control at each OPTION adjustment mode.
2)At each OPTION Mode, Select adjustment item by the CH D, E button and then set up each OPTION by the F, G button.