29
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
Communication Parameters

Baud rate: 9600 bps (UART)

Data length: 8 bits

Parity : None

Stop bit: 1 bit

Communication code: ASCII code

Use a null modem cable.

Command Reference List
COMMAND1 COMMAND2 DATA
(Hexadecimal) COMMAND1 COMMAND2 DATA
(Hexadecimal)
01. Power k a 00 - 01 14. Balance k t 00 - 64
02. Input
Select x b (See p. 31) 15. 3D (For
3D TV) x t (See p. 32)
03. Aspect
Ratio k c (See p. 31) 16. Color
Temperature x u 00 - 64
04. Screen
Mute k d 00 - 01
17. Extended
3D (For 3D
TV)
x v (See p. 33)
05. Volume
Mute k e 00 - 01 18. Auto
Configuration j u (See p. 33)
06. Volume
Control k f 00 - 64 20. Channel
Add/Del m b 00 - 01
07. Contrast k g 00 - 64 21. Key m c (See p. 34)
08.
Brightness k h 00 - 64 22. Backlight m g 00 - 64
09. Color k i 00 - 64 23. Equalize j v (See p. 34)
10. Tint k j 00 - 64
11.
Sharpness k k 00 - 32
12. OSD
Select k l 00 - 01
13. Remote
Control
Lock Mode
k m 00 - 01
COMMAND1 COMMAND2
DATA00
(Hexadecimal)
DATA01
(Hexadecimal)
DATA02
(Hexadecimal)
DATA03
(Hexadecimal)
DATA04
(Hexadecimal)
DATA05
(Hexadecimal)
19.
Channel
Tuning
m a
physical
program
high
major
program
low
major low minor high minor low attribute