Test Running

Test Running

1.Check that all tubing and wiring have been properly connected.

2.Check that the gas and liquid side service valves are fully open.

Prepare remote control

1. Remove the battery cover by pulling it according to the arrow direction.

2. Insert new batteries making sure that the (+) and (–) of battery are installed correctly.

3. Reattach the cover by pushing it back into position.

NOTE:

Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.

Remove the batteries from the remote control if the system is not going to be used for a long time.

Settlement of outdoor unit

Anchor the outdoor unit with a bolt and

nut(ø10mm(0.39in) tightly and horizontally on a concrete or rigid mount.

When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake.

In the case when the vibration of the unit is conveyed to the hose, secure the unit with an anti- vibration rubber.

Bolt

Tubing connection

Evaluation of the performance

Operate unit for 15~20 minutes, then check the system refrigerant charge:

1.Measure the pressure of the gas side service valve.

2.Measure the temperature of the intake and discharge of air.

3.Ensure the difference between the intake temperature and the discharge is more than 46.4°F(8°C) (Cooling) or (Heating).

Intake temperature

Discharge air

Discharge

temperature

4.For reference; the gas side pressure of optimum condition is as below.(Cooling)

Outside ambient TEMP.

The pressure of the gas side service valve

 

 

95°F(35°C)

8.5~9.5kg/cm2 G(120~135 P.S.I.G.)

NOTE: If the actual pressure are higher than shown, the system is most likely over- charged, and charge should be removed. If the actual pressure are lower than shown, the system is most likely undercharged, and charge should be added.

The air conditioner is now ready for use.

PUMP DOWN

This is performed when the unit is to be relocated or the refrigerant circuit is serviced.

Pump Down means collecting all refrigerant in the outdoor unit without loss of refrigerant.

CAUTION:

Be sure to perform Pump Down procedure with the unit cooling mode.

Pump Down Procedure

1.Connect a low-pressure gauge manifold hose to the charge port on the gas side service valve.

2.Open the gas side service valve halfway and purge the air from the manifold hose using the refrigerant gas.

3.Close the liquid side service valve(all the way in).

4.Turn on the unit's operating switch and start the cooling operation.

5.When the low-pressure gauge reading becomes 1 to 0.5kg/cm2 G(14.2 to 7.1 P.S.I.G.), fully close the gas side valve stem and then quickly turn off the unit. At that time, Pump Down has been completed and all refrigerant will have been collected in the outdoor unit.

30Room Air Conditioner

Page 30
Image 30
LG Electronics 3828A30087S installation manual Test Running, Pump Down Procedure

3828A30087S specifications

The LG Electronics 3828A30087S is a notable appliance component that caters to a broad spectrum of appliances, specifically designed to enhance appliance efficiency and functionality. This particular part is recognized for its compatibility, mainly with LG refrigerators, ensuring that users experience optimal conditions for food preservation.

One of the primary features of the 3828A30087S is its critical role in the refrigerator's cooling system. As a key component, it is responsible for regulating temperature, which is crucial for maintaining the quality and freshness of food items stored within. The part is designed to operate seamlessly within the appliance, promoting energy efficiency while ensuring consistent cooling performance.

The technology behind the 3828A30087S is rooted in LG's commitment to innovation and customer satisfaction. The features include an advanced design that enhances durability, reducing the frequency of replacements and repairs. The component is manufactured using high-quality materials known for their resilience, ensuring longevity and optimal performance under various operating conditions.

Installation of the 3828A30087S is straightforward, making it accessible for homeowners looking to undertake DIY appliance repairs. With proper guidance, users can enjoy a hassle-free installation process, minimizing downtime and restoring appliance functionality swiftly.

In addition to its functional attributes, the 3828A30087S is characterized by its energy-efficient operation, which aligns with modern energy standards, helping consumers to lower their energy bills while being environmentally conscious. This emphasis on sustainability is a key aspect of LG’s brand ethos, reflecting a commitment to producing appliances that not only perform well but also contribute to a greener planet.

Customers appreciate the reliability of LG products, and the 3828A30087S continues this legacy by ensuring that refrigerators operate at peak efficiency. With its combination of innovative technology, robust design, and user-friendly installation, this component stands out as a vital part that enhances the overall performance of LG refrigerators.

In conclusion, the LG Electronics 3828A30087S exemplifies the brand's dedication to quality and performance. Its impressive features, advanced cooling technology, and focus on energy efficiency make it an essential component for anyone looking to maintain their appliance effectively.