Installation

AirPurging

Air and moisture remaining in the refrigerant system have undesirable effects as indicated below.

Pressure in the system rises.

Operating current rises.

Cooling(or heating) efficiency drops.

Moisture in the refrigerant circuit may freeze and block capillary tubing.

Water may lead to corrosion of parts in the refrigeration system.

Therefore, the indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any noncondensables and moisture from the system.

AirpurgingWithVacuumPump

Preparation

• Do a leak test of all joints of the tubing(both indoor

 

and outdoor) and both gas and liquid side service

• Check that each tubing(both liquid and gas side

valves.

tubes) between the indoor and outdoor units have

Bubbles indicate a leak. Be sure to wipe off the soap

been properly connected and all wiring for the test

with a clean cloth.

run has been completed. Remove the service

• After the system is found to be free of leaks, relieve

valve caps from both the gas and the liquid side

the nitrogen pressure by loosening the charge hose

on the outdoor unit. Note that both the liquid and

connector at the nitrogen cylinder. When the system

the gas side service valves on the outdoor unit are

pressure is reduced to normal, disconnect the hose

kept closed at this stage.

from the cylinder.

ENGLISH

Leak test

Connect the manifold valve(with pressure gauges) and dry nitrogen gas cylinder to this service port with charge hoses.

CAUTION

Be sure to use a manifold valve for air purging. If it is not available, use a stop valve for this purpose. The "Hi" knob of the manifold valve must always be kept close.

Pressurize the system to no more than 150 P.S.I.G. with dry nitrogen gas and close the cylinder valve when the gauge reading reached 150 P.S.I.G. Next, test for leaks with liquid soap.

CAUTION

To avoid nitrogen entering the refrigerant system in a liquid state, the top of the cylinder must be higher than its bottom when you pressurize the system.

Usually, the cylinder is used in a vertical standing position.

Indoor unit

Outdoor unit

Manifold valve

Pressure

 

 

gauge

Lo

Hi

Charge hose

Nitrogen gas cylinder(in vertical standing position)

Installation Manual 27

Page 27
Image 27
LG Electronics 3828A30087S installation manual Air Purging, Air purging With Vacuum Pump

3828A30087S specifications

The LG Electronics 3828A30087S is a notable appliance component that caters to a broad spectrum of appliances, specifically designed to enhance appliance efficiency and functionality. This particular part is recognized for its compatibility, mainly with LG refrigerators, ensuring that users experience optimal conditions for food preservation.

One of the primary features of the 3828A30087S is its critical role in the refrigerator's cooling system. As a key component, it is responsible for regulating temperature, which is crucial for maintaining the quality and freshness of food items stored within. The part is designed to operate seamlessly within the appliance, promoting energy efficiency while ensuring consistent cooling performance.

The technology behind the 3828A30087S is rooted in LG's commitment to innovation and customer satisfaction. The features include an advanced design that enhances durability, reducing the frequency of replacements and repairs. The component is manufactured using high-quality materials known for their resilience, ensuring longevity and optimal performance under various operating conditions.

Installation of the 3828A30087S is straightforward, making it accessible for homeowners looking to undertake DIY appliance repairs. With proper guidance, users can enjoy a hassle-free installation process, minimizing downtime and restoring appliance functionality swiftly.

In addition to its functional attributes, the 3828A30087S is characterized by its energy-efficient operation, which aligns with modern energy standards, helping consumers to lower their energy bills while being environmentally conscious. This emphasis on sustainability is a key aspect of LG’s brand ethos, reflecting a commitment to producing appliances that not only perform well but also contribute to a greener planet.

Customers appreciate the reliability of LG products, and the 3828A30087S continues this legacy by ensuring that refrigerators operate at peak efficiency. With its combination of innovative technology, robust design, and user-friendly installation, this component stands out as a vital part that enhances the overall performance of LG refrigerators.

In conclusion, the LG Electronics 3828A30087S exemplifies the brand's dedication to quality and performance. Its impressive features, advanced cooling technology, and focus on energy efficiency make it an essential component for anyone looking to maintain their appliance effectively.