LG Electronics 42LA69**-Z* Adjustment Instruction, Application Range, Designation, LAN Inspection

Models: 42LA69**-Z*

1 23
Download 23 pages 33.22 Kb
Page 13
Image 13

ADJUSTMENT INSTRUCTION

1. Application Range

This specification sheet is applied to all of the LED TV with LD33B chassis.

2.Designation

(1)Because this is not a hot chassis, it is not necessary to use an isolation transformer. However, the use of isolation transformer will help protect test instrument.

(2)Adjustment must be done in the correct order.

(3)The adjustment must be performed in the circumstance of 25 °C ± 5 °C of temperature and 65 % ± 10 % of relative humidity if there is no specific designation.

(4)The input voltage of the receiver must keep AC 100-240 V~, 50/60 Hz.

(5)The receiver must be operated for about 5 minutes prior to the adjustment when module is in the circumstance of over 15.

In case of keeping module is in the circumstance of 0 °C, it should be placed in the circumstance of above 15 °C for 2 hours.

In case of keeping module is in the circumstance of below -20 °C, it should be placed in the circumstance of above 15 °C for 3 hours.

[Caution]

When still image is displayed for a period of 20 minutes or longer (Especially where W/B scale is strong. Digital pattern 13ch and/or Cross hatch pattern 09ch), there can some afterimage in the black level area.

3. Automatic Adjustment

3.1. MAC address D/L, CI+ key D/L, Widevine key D/L, ESN D/L, HDCP14/20 D/L

Connect: USB port

Communication Prot connection

Com 1,2,3,4 and 115200(Baudrate) Mode check: Online Only

Check the test process: DETECT -> MAC -> CI -> Widevine -> ESN -> HDCP14 -> HDCP20

Play: Press Enter key

Result: Ready, Test, OK or NG

Printer Out (MAC Address Label)

3.2. LAN Inspection

3.2.1. Equipment & Condition

▪ Each other connection to LAN Port of IP Hub and Jig

3.2.2. LAN inspection solution

LAN Port connection with PCB

Setting automatic IP

If you want manual connection, enter Network connection at MENU Mode of TV. Press Start connection key, then Network will be connected.

Setting state confirmation

-If automatic setting is finished, you confirm IP and MAC Address at ‘in start’ menu mode.



Copyright ©

LG Electronics. Inc. All rights reserved.

- 13 -

LGE Internal Use Only

Only for training and service purposes

 

 

Page 13
Image 13
LG Electronics 42LA69**-Z* Adjustment Instruction, Application Range, Designation, Automatic Adjustment, LAN Inspection