19. Abnormal State (Command 2 : z)

G To recognize an abnormal state.

Transmission

[k][z][ ][Set ID][ ][FF][ ][Cr]

Data FF : Read

Ack

[z][ ][Set ID][ ][OK][Data][x]

Data 0: Normal (Power on and signal exist)

1:No signal (Power on)

2:Turn the monitor off by remote control

3:Turn the monitor off by sleep time function

4:Turn the monitor off by RS-232C function

5:5V down

6:AC down

7:Turn the monitor off by Fan Alarm function

8:Turn the monitor off by Off time function

9:Turn the monitor off by Auto sleep function * This function is “read only”.

20. ISM Method

(Command 1 : j, Command 2 : p)

GTo control the ISM method. You can also adjust ISM Method in OPTION menu.

It’s not available to use this function in LCD TV models.

Transmission

[j][p][

][Set ID][ ][Data][Cr]

 

Data 0:

Normal

2: Orbiter

1:

White wash

3: Inversion

Ack

[p][ ][Set ID][ ][OK/NG][Data][x]

21. Low Power

(Command 1 : j, Command 2 : q)

G To reduce the power consumption of the set. You can also adjust Low Power in OPTION menu.

It’s not available to use this function in LCD TV models.

Transmission

[j][q][ ][Set ID][ ][Data][ ][Cr]

Data 0 : Off

1 : On

Ack

[q][ ][Set ID][ ][OK/NG][Data][x]

* Real data mapping 1

0 : Step 0

A : Step 10 (Set ID 10)

F: Step 15 (Set ID 15)

10 : Step 16 (Set ID 16)

64:Step 100 6E : Step 110

73 : Step 115

74 : Step 116

C7: Step 199

FE : Step 254

FF : Step 255

*Real data mapping 2

0 : -40

1 : -39

2 : -38

28 :0

4E : +38

4F : +39

50 : +40

APPENDIX

113

Page 115
Image 115
LG Electronics 37LC5, 60PC4, 42LC5, 37LC4, 32LC5, 26LB7, 26LC5, 26LC4, 32LC4, 32LB7, 42LC4, 42PC3, 42PC5, 50PC5, 50PB6, 50PC3 113