LG Electronics 42LG50, 60PG30, 50PG20 Baud rate 9600 bps Uart Stop bit 1 bit Data length 8 bits

Models: 26LG30 37LG50 42LG50 47LG50 32LG50 42PG30 50PG10 22LS4D 52LG50 32LG30 37LG30 42PG10 19LG30 42LG30 19LS4D 22LG30 50PG30 42PG20 60PG30 50PG20

1 118
Download 118 pages 59.2 Kb
Page 113
Image 113

Communication Parameters

A Baud rate : 9600 bps (UART)

A Stop bit : 1 bit

A Data length : 8 bits

A Communication code : ASCII code

A Parity : None

A Use a crossed (reverse) cable.

Command Reference List

COMMAND COMMAND

DATA

 

 

1

2

(Hexadecimal)

 

 

 

 

 

 

01. Power

k

a

00

~

01

02. Aspect Ratio

k

c

Refer to p. 112

03. Screen Mute

k

d

00

~

01

04. Volume Mute

k

e

00

~

01

05. Volume Control

k

f

00

~

64

06. Contrast

k

g

00

~

64

07. Brightness

k

h

00

~

64

08. Colour

k

i

00

~

64

09. Tint

k

j

00

~

64

10. Sharpness

k

k

00

~

64

11. OSD Select

k

l

00

~

01

12. Remote control lock mode

k

m

00

~

01

13. Balance

k

t

00

~

64

14. Colour Temperature

k

u

00

~

02

15. Abnormal Status

k

z

00

~

09

16. ISM Method

j

p Refer to p. 114

17. Power Saving

j

q

00

~

04

18. Auto Configure

j

u

 

01

19. Equalize

j

v Refer to p. 114

20. Tune Command

m

a Refer to p. 114

21. Channel Add/Skip

m

b

00

~ 01

22. Key

m

c

Key Code

23. Control Back Light

m

g

00

~ 64

24. Input select (Main)

x

b Refer to p. 115

* When setting the 15 ~ 24, a menu does not appear on screen.

Transmission / Receiving Protocol

Transmission

[Command1][Command2][ ][Set ID][ ][Data][Cr]

*[Command 1] : First command to control the TV. (j, k, m or x)

*[Command 2] : Second command to control the TV.

*

[Set ID]

: You can adjust the set ID to choose

 

 

desired monitor ID number in option

 

 

menu. Adjustment range is 1 ~ 99.

 

 

When selecting Set ID ‘0’, every

 

 

connected set is controlled.

 

 

Set ID is indicated as decimal (1~99)

 

 

on menu and as Hexa decimal

 

 

(0x0~0x63) on transmission/

 

 

receiving protocol.

*

[DATA]

: To transmit command data.

 

 

Transmit ‘FF’ data to read status of

 

 

command.

*

[Cr]

: Carriage Return

 

 

ASCII code ‘0x0D’

*

[ ]

: ASCII code ‘space (0x20)’

OK Acknowledgement

[Command2][ ][Set ID][ ][OK][Data][x]

*The TV transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC computer.

Error Acknowledgement

[Command2][ ][Set ID][ ][NG][Data][x]

*The TV transmits ACK (acknowledgement) based on this format when receiving abnormal data from nonviable functions or communication errors.

APPENDIX

111

Downloaded From TV-Manual.com Manuals

Page 113
Image 113
LG Electronics 42LG50 Baud rate 9600 bps Uart Stop bit 1 bit Data length 8 bits, Parity None Use a crossed reverse cable