LG Electronics D 5988W, DLE 5977W, DLE 5977 B, D 5988 B owner manual wire connection Direct wire

Models: D 5988W

1 32
Download 32 pages 40.25 Kb
Page 15
Image 15
3-wire connection : Direct wire

4.Put the hooked shape ends of the wire under the screw of the terminal block(hooked end facing rightward) and squeeze the hook together and screw tightly.

5.Put the hooked shaped ends of the other power supply cable wires under the outer terminal block

screws(hooked end facing right) and squeeze the hooked ends together and screw tightly.

6.Tighten strain relief screws.

7.Place the tab of terminal block cover into slot of dryer rear panel. Make sure cover with screw.

3-wire connection : Direct wire

Important : The places wherea 4-wire connection is needed are mobile homes and areas that local codes do not admit the use of 3-wire connections.

At least, 5ft(1.52m) of extra length is required for dryer to be able to move.

Peel 5 in (12.7cm) of external covering from end

of cable, leaving bare ground wire at 5 in (12.7cm). Cut 11/2 in. (3.8cm) from 3 remaining wires. Strip insulation back lin. (2.5cm). Shape ends of wires into a hook shape.

Then, put the hooked shape end of the wire under the screw of the terminal block(hooked end facing rightward) and pinch the hook together and screw tightly.

1.Take off center terminal block screw

2.Put the hooked end of the neutral wire(white) of power supply cable under the center screw of terminal block). Squeeze the hooked end together

3.Connect the hooked ends of the other power supply cable to the center screw of terminal block.

4.Screw strain relief tightly.

5.Place tab of terminal block cover into slot of dryer rear panel. Make sure cover with screw.

a.External ground connector

b.Neutral grounding wire (white)

c.Center silver-colored terminal block screw

d.Neutral wire (white or center wire)

e.3/4in. (!.9cm) UL-listed strain relief