IMPORTANT NOTE: All gas piping must be done by a licensed plumber or gas fitter and must conform to the requirements of the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition
Gas connection: The heater gas inlet connection is 3/8” NPT at the regulator, located below the burner, in the center of the heater.
There are four possible entry points for the gas supply
To ensure customer safety, be sure to design the installation so that the strength of both the wall and any wall fixings used are sufficient. Lennox Hearth Products assumes no responsibility for injuries and damages that may occur due to improper installation or handling.
The appliance should not be installed until all dry wall sanding and wall painting has been completed.
Incorrect installation can cause the appliance to fall from the wall and cause injury. Do not block the ventilation holes of the appliance. The wall onto which the appliance is installed must be flat.
Install only on a vertical surface. Avoid sloped surfaces. Installation onto anything other than a vertical wall may result in fire, damage or injury.
A full size fitting template is supplied to assist with
POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL
COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED
If a concealed gas connection is to be made, the supply pipe should always be sleeved through walls and floors using the shortest possible route.
For concealed supply pipe routing, pipes must (where possible) be vertical and providing there is sufficient wall thickness available, they should be placed in pipe chases. Horizontal pipe runs should be avoided. Prior to chasing a solid wall, an inspection should be made to note the proximity of any cables/sockets outlets which may already be buried. Pipes must
WARNING
CLEARANCES FROM COMBUSTIBLE MATERIALS The following clearances must be maintained at all times. Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual provided with the heater.
Clearance to combustible ceiling 32” measured from top of appliance glass panel
Clearance in front of
heater 20”Clearance to combustible sidewalls 4” (both sides)
Note : Zero clearance from bottom of heater frame required for hard combustible floors. Minimum 4” clearance required to rugs or any fabric floor coverings. REFER TO INSTRUCTION MANUAL
IMPORTANT : Fabrics, curtains and drapes are not permited above the heater at any distance and within 20” of the heater sides. No combustible shelves of any size are permitted above the heater.
ADVERTENCIA
ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES
Deben mantenerse en todo momento los siguientes espacios libres. El no hacerlo puede causar un riesgo de incendio. Consulte el manual de instrucciones suministrado con este aparato para obtener información completa.
El espacio de 32” hasta un techo combustible se mide desde el borde superior del panel de vidrio del aparato
Espacio libre delante del
calentador 20”Espacio hasta paredeslaterales combustibles 4” (ambos lados)
IMPORTANTE: No se permite la colocación de telas, cortinas y similares por encima del calentador a cualquier distancia, ni a una distancia de 20” de los laterales del calentador. No se permiten estantes combustibles de cualquier tamaño por encima del calentador.
FIXING POINTS
PIERCE TEMPLATE TO MARK
HOLE POSITION ON WALL X 4
PUNTOS DE SUJECION
PERFORE LA PLANTILLA PARA MARCAR
LA POSICION DE LOS 4 TALADROS EN LA PARED
Elite™ CVF
WALL MOUNTED VENT FREE FITTING TEMPLATE PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS
IMPORTANT
THIS APPLIANCE IS TO BE WALL HUNG ONLY.
DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.
THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY. DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.
IMPORTANTE
ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.
NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.
ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.
RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.
CENTRO
LINEA DE
CENTRE LINE
FIXING POINTS
PUNTOS DE SUJECION
FIREBOX OUTLINE CONTORNO DE LA CAMARA DE COMBUSTION | APPLIANCE OUTLINE CONTORNO DE LA APARATO |
|
|
be secured using suitable clips and protected against corrosion. Ideally factory finished protected
After having selected the final mounting position of the appliance, taking into account the site requirements as specified in section 9.0 of these instructions, the integrity of the wall, and the feasibility of the proposed supply pipe routing, the appliance firebox may be secured to the wall.
WARNING
The wall where the appliance is to be installed must be capable of
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Figure 2 | CONCEALED GAS INLET |
| ENTRADA DE GAS OCULTA |
DO 005860/0 - ISSUE A
Mark the positions shown as “Fixing Points” on the wall. If the appliance is to be mounted on the inner leaf of a conventional cavity wall, or a solid wall, drill four holes using a 5/16" masonry bit, to a depth of
If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product. These should be constructed from metal and not plastic.
If a concealed gas connection is to be made ensure the gas supply pipe is in it’s final position and can enter the appliance in the correct position when the appliance is hung on the wall.
Insert the