10.0 PREPARING THE APPLIANCE

IMPORTANT NOTE: All gas piping must be done by a licensed plumber or gas fitter and must conform to the requirements of the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition

Gas connection: The heater gas inlet connection is 3/8” NPT at the regulator, located below the burner, in the center of the heater.

There are four possible entry points for the gas supply pipe-work to enter the appliance firebox. These entry points are ‘knock out’ type holes (shown in Figure 1).

To ensure customer safety, be sure to design the installation so that the strength of both the wall and any wall fixings used are sufficient. Lennox Hearth Products assumes no responsibility for injuries and damages that may occur due to improper installation or handling.

The appliance should not be installed until all dry wall sanding and wall painting has been completed.

Incorrect installation can cause the appliance to fall from the wall and cause injury. Do not block the ventilation holes of the appliance. The wall onto which the appliance is installed must be flat.

Install only on a vertical surface. Avoid sloped surfaces. Installation onto anything other than a vertical wall may result in fire, damage or injury.

A full size fitting template is supplied to assist with wall-mounting.

POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL

COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED

Figure 1 - Gas Supply Entry Points

Non-concealed gas connections may be made using the entry points on the sides or base of the firebox. A concealed gas connection may be made using the knock out hole in the center back of the firebox. Select the most appropriate entry point and knock out the relevant hole.

If a concealed gas connection is to be made, the supply pipe should always be sleeved through walls and floors using the shortest possible route.

For concealed supply pipe routing, pipes must (where possible) be vertical and providing there is sufficient wall thickness available, they should be placed in pipe chases. Horizontal pipe runs should be avoided. Prior to chasing a solid wall, an inspection should be made to note the proximity of any cables/sockets outlets which may already be buried. Pipes must

WARNING

CLEARANCES FROM COMBUSTIBLE MATERIALS The following clearances must be maintained at all times. Failure to do so may result in the risk of a fire.

For full information refer to the instruction manual provided with the heater.

Clearance to combustible ceiling 32” measured from top of appliance glass panel

Clearance in front of

heater 20”Clearance to combustible sidewalls 4” (both sides)

Note : Zero clearance from bottom of heater frame required for hard combustible floors. Minimum 4” clearance required to rugs or any fabric floor coverings. REFER TO INSTRUCTION MANUAL

IMPORTANT : Fabrics, curtains and drapes are not permited above the heater at any distance and within 20” of the heater sides. No combustible shelves of any size are permitted above the heater.

ADVERTENCIA

ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES

Deben mantenerse en todo momento los siguientes espacios libres. El no hacerlo puede causar un riesgo de incendio. Consulte el manual de instrucciones suministrado con este aparato para obtener información completa.

El espacio de 32” hasta un techo combustible se mide desde el borde superior del panel de vidrio del aparato

Espacio libre delante del

calentador 20”Espacio hasta paredeslaterales combustibles 4” (ambos lados)

IMPORTANTE: No se permite la colocación de telas, cortinas y similares por encima del calentador a cualquier distancia, ni a una distancia de 20” de los laterales del calentador. No se permiten estantes combustibles de cualquier tamaño por encima del calentador.

20-1/4” (515mm)

9-3/16” (234mm)

FIXING POINTS

PIERCE TEMPLATE TO MARK

HOLE POSITION ON WALL X 4

PUNTOS DE SUJECION

PERFORE LA PLANTILLA PARA MARCAR

LA POSICION DE LOS 4 TALADROS EN LA PARED

EliteCVF

WALL MOUNTED VENT FREE FITTING TEMPLATE PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS

IMPORTANT

THIS APPLIANCE IS TO BE WALL HUNG ONLY.

DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE.

THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY. DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE.

IMPORTANTE

ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED.

NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO.

ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION.

RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.

CENTRO

LINEA DE

CENTRE LINE

FIXING POINTS

PUNTOS DE SUJECION

1-1/8” (28mm)

FIREBOX OUTLINE CONTORNO DE LA CAMARA DE COMBUSTION

APPLIANCE OUTLINE CONTORNO DE LA APARATO

 

 

be secured using suitable clips and protected against corrosion. Ideally factory finished protected pipe-work and fittings should be used. Joints should be kept to a minimum and compression fittings must not be used. The pipe-work installation must be tested for soundness before any protection is applied and/or the pipe-work and fittings are buried.

11.0 MOUNTING THE APPLIANCE

After having selected the final mounting position of the appliance, taking into account the site requirements as specified in section 9.0 of these instructions, the integrity of the wall, and the feasibility of the proposed supply pipe routing, the appliance firebox may be secured to the wall.

WARNING

The wall where the appliance is to be installed must be capable of long-term support of the total load of the appliance. Measures should also be taken to ensure sufficient strength to withstand the force of earthquakes, vibration and other external forces.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Figure 2

CONCEALED GAS INLET

 

ENTRADA DE GAS OCULTA

DO 005860/0 - ISSUE A

Mark the positions shown as “Fixing Points” on the wall. If the appliance is to be mounted on the inner leaf of a conventional cavity wall, or a solid wall, drill four holes using a 5/16" masonry bit, to a depth of 1-11/16". Insert the wall plugs provided. Note: Special "screw fixings" are not required if installed directly into vertical studs. We recommend that this appliance should be secured to a stud on at least one side while the other side can be secured to the wall with the "screw fixings".

If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product. These should be constructed from metal and not plastic.

If a concealed gas connection is to be made ensure the gas supply pipe is in it’s final position and can enter the appliance in the correct position when the appliance is hung on the wall.

Insert the wall-mounting screws into the top wall plugs, taking care to leave the screws protruding approximately 3/8” from the wall. Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance.