LG Electronics ESG-2008-V1 Flex MULTI-SPLIT DUAL-ZONE & TRI-ZONE, Electrical Specifications

Models: ESG-2008-V1

1 24
Download 24 pages 34.22 Kb
Page 16
Image 16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLEX MULTI-SPLITDUAL-ZONE & TRI-ZONE

 

 

 

 

 

 

 

CEILING CASSETTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor

Outdoor

Amps

 

 

 

 

 

 

 

 

 

ELECTRICAL & REFRIGERATION QUICK REFERENCE

 

 

 

 

 

 

DUCT-FREE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLOOR STANDING &

 

 

 

 

 

 

 

Electrical Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR CONDITIONING

 

 

 

 

 

 

A/C

LMN090CE

9,000

36V DC

0.5

 

 

 

 

 

 

Type

Model

BTUs

Voltage

Rated

MCA*

MOP**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEMS

 

 

 

 

 

Units

A/C

LMN120CE

12,000

36V DC

0.5

 

 

 

 

 

Flex Multi-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Split Indoor

A/C

LMAN090CNS

9,000

36V DC

1.3

 

 

 

 

 

 

 

 

A/C

LMAN120CNS

12,000

36V DC

1.3

 

High-Capacity Split Systems

 

 

 

 

 

 

A/C

LMAN121CNM

12,000

36V DC

0.5

 

 

 

 

 

 

 

 

 

The Floor Standing and Ceiling Cassette models

 

 

 

 

 

 

H/P

LMN090HE

9,000

36V DC

0.5

 

 

 

 

 

 

 

 

are ideal for light commercial applications and

 

 

 

 

 

 

H/P

LMAN090HNS

9,000

36V DC

1.3

 

 

 

 

 

 

 

 

work well in large, open spaces. The Ceiling

 

 

 

 

 

 

H/P

LMN120HE

12,000

36V DC

0.5

 

 

 

 

 

 

 

 

Cassette is a useful alternative when floor space

 

 

 

 

 

 

H/P

LMAN120HNS

12,000

36V DC

1.3

 

 

 

 

 

 

 

 

is limited.

 

 

 

 

 

 

H/P

LMAN121HNM

12,000

36V DC

0.5

 

 

 

 

 

 

 

 

 

 

Duct-Free Split

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The outdoor unit for both models operate on

 

Floor Standing Indoor Units

 

 

 

Outdoor

A/C

LMU180CE

18,000

 

 

 

230/208

8.8

15

20

 

 

 

 

 

 

 

 

 

 

 

 

high-voltage (230/208) power and models one

 

White Finish

 

 

 

Units

A/C

LMU240CE

24,000

 

 

 

230/208

10.2

20

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or two compressors, depending on the size.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A/C

LMU360CE

36,000

 

 

 

230/208

16.6

30

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H/P

LMU180HE

18,000

 

 

 

230/208

8.8

15

20

 

 

 

 

 

 

 

 

 

 

H/P

LMU240HE

24,000

 

 

 

230/208

10.2

20

25

 

 

 

 

 

 

 

 

 

 

H/P

LMU360HE

36,000

 

 

 

230/208

16.6

30

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All equipment are single phase.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire Size

 

 

 

 

 

 

 

 

 

NOTE: Please see local electrical codes for proper wire specifications.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum wiring requirements suggested by manufacturer

 

 

 

 

 

 

*Minimum Circuit Ampacity **Maximum Overcurrent Protection ***For LMU360CE,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum AWG

 

 

14-3

 

 

 

 

 

 

 

 

LMU360HE

 

 

 

 

 

 

 

 

 

12-3***

 

 

 

 

 

Duct-Free Split

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor/Outdoor Connecting Cable Minimum AWG 18-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling Cassette Indoor Units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White Finish

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Line & Formula Specifications

 

 

 

 

 

 

 

 

Pipe size

Additional

Max. Pipe

Max.

 

 

 

Type

Model

BTUs

Liquid Suction

Refrigerant

Length

Elevation

 

 

Flex Multi-

A/C

LMN090CE

9,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

Split

A/C

LMAN090CNS

9,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

 

A/C

LMN120CE

12,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

 

A/C

LMAN120CNS

12,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

 

A/C

LMAN121CNM

12,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

 

H/P

LMN090HE

9,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

 

H/P

LMAN090HNS

9,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

 

H/P

LMN120HE

12,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

 

H/P

LMAN120HNS

12,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

 

 

 

H/P

LMAN121HNM

12,000

1/4"

3/8"

0.22 oz./ft.

50'

25'

24,000 BTUs

34,000 BTUs

 

 

 

 

 

 

 

 

44,000 BTUs

NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement installations) have the following

 

 

 

 

 

 

 

24,000 BTUs

 

 

OUTDOOR UNIT

Figure A.

Single-ZoneSplit Systems

Single-ZoneSplit Systems

additional requirement: For systems with maximum elevation of 25 ft. (see chart above and Figure A), refrigerant lines

 

 

 

 

 

 

Example: 25 ft.

Floor Standing

Ceiling Cassette

must be oil-trapped between 8 ft. and 16.4 ft. of elevation. For systems with elevation of greater than 25 ft. (see chart

OIL TRAP

 

 

 

 

 

maximum

 

 

above), refrigerant lines must be oil-trapped at least every 16.4 ft. of elevation.

 

 

 

 

 

 

 

 

 

 

 

 

 

elevation.

 

 

Dual-Zone: Exterior unit has sufficient refrigerant for charging two indoor coils and a 25 ft. line set per indoor unit.

INDOOR UNIT

 

 

 

 

25' maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tri-Zone: Exterior unit has sufficient refrigerant for charging three indoor coils and a 25 ft. line set per indoor unit.

 

 

 

 

 

8' minimum

 

 

 

 

 

 

 

 

16.4' maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLOOR STANDING & CEILING CASSETTE

29

30

Page 16
Image 16
LG Electronics ESG-2008-V1 specifications Flex MULTI-SPLIT DUAL-ZONE & TRI-ZONE, Electrical Specifications, Wire Size