Service Manual 417. Cooling or Heating Mode with Sleep Mode Auto Control
When selecting the Cooling( ) or the Heating( ) combined with the Sleep Mode Auto Control( ), the
operation diagram is as following.
Cooling Mode with the Sleep Mode
The setting temperature will be automatically raised by 2°F 30 minutes later and by 4
°
F 1 hour later.
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Heating Mode with the Sleep Mode(only Heating Model)
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
INTAKE AIR TEMP.
SETTING TEMP. +1
°
F
(Compressor ON)
SETTING TEMP. -1
°
F
(Compressor OFF)
30 minutes 30 minutes
More than
3 minutes
2°F
2°F
More than
3 minutes
COMPRESSOR ON OFF ON OFF ON
INDOOR FAN SPEED Low Low Low Low Low
SETTING TEMP. +6
°
F
(Compressor OFF)
SETTING TEMP.
(Compressor ON)
COMPRESSOR ON OFF ON OFF ON OFF
INDOOR FAN SPEED Med Low or OFF Med Low or OFF Med Low or OFF
INTAKE AIR TEMP.
More than
3 minutes
More than
3 minutes
More than
3 minutes
Operation