6
Part 3 ELECTRICAL CONNECTIONS
Protection cover
The Cord/Conduit connection plate is used for the
installation of power cord or conduit. For power cord,
install it with the connection plate as INSTALLED. For
conduit, remove the connection plate located below the
rear of the drawer body and use the conduit hole (1
1
/
8
”)
instead of power cord hole (1
3
/
8
”). (Refer to Figure 5 and 6.)
3, 4 - Wire electrical wall Receptacle
CONNECT RANGE CORD
The Rear Access cover must be removed. Loosen the
three screws with a screwdriver. The terminal block
will then be accessible.
Protection cover
FIGURE 3
FIGURE 4
Range rating, watts
Specified rating
of power-supply-
cord kit, amperes
120/240 volts
3-wire
8,750 - 16,500
16,501 - 22,500
120/208 volts
3-wire
7,801 - 12,500
12,501 - 18,500
40 or 50A
50
Diameter (inches) of Range
connection Opening
Conduit
11/8
13/8
Power cord
13/8
13/4
Specified power-supply-cord kit rating

ELECTRICAL CONNECTION

REQUIREMENTS

This appliance must be installed and grounded on a branch
circuit by a qualified technician in accordance with the
National Electrical code ANSI/NFPA NO. 70 - latest edition.
A
ll wiring should conform to Local and NEC. This range
requires a single-phase, 3 wire, A.C 120/208V or 120/240V 60Hz
electrical system. Use only a 3-conductor or a 4-conductor
UL-listed range cord with closed-loop terminals, open-end
spade lugs with upturned ends or similar termination. DO
NOT install the power cord without a strain relief.
A range cord rated at 40 amps with 120/240 minimum volt
range is required. If a 50 amp range cord is used, it should
be marked for use with 1
3
8
” diameter connection openings.
This appliance may be connected by means of conduit or
power cord. If conduit is being used, go to page 7 for 3 wire
conduit connections or page 8 for 4 wire conduit connections.
WARNING

New branch-circuit installations (1996 NEC)

for mobile homes, recreational vehicles, and

installations where local codes do not allow

grounding through the neutral wire require a

4-conductor UL listed range cord or 4 wire

conduit connection.

Power supply cord and plug should not be

modified. If it will not fit the outlet, have a proper

outlet Installed by a qualified electrician.

Using an extension cord to connect the power is

prohibited. The way to connect the power cord

and plug directly is strongly recommended.

Electrical ground is required on this appliance.

You should make sure that the power cord is

not pinched by the range or heavy objects.

-

Failure to do so can result in serious burns or electrical shock.

Gloves
Safety Glasses
Tape Measure
Pencil
Rear filler & 2 Screws
(LSE Series only)
Protection cover
Protection cover
FIGURE 5
FIGURE 6
Remove the Conduit connection plate
Assemble the
strain relief hole
Reinstall the Cord/Conduit connection plate
WARNING

You never remove the protection cover

covering the rear of lower oven.

-

Failure to do so can result in serious damage to power cord.

The damage causes serious burns and electric shock.

Gloves
Safety Glasses
Tape Measure
Pencil
Rear filler & 2 Screws
(LSE Series only)
4 Wire receptacle (14-50R)3 Wire receptacle (10-50R)3 4