 3-wire connection with a power supply cord

Part 3 ELECTRICAL CONNECTIONS

Separate Strain ReliefInstall the power cord as follows: 3-wire connection with a power supply cord DO NOT install the power cord without a strain relief.Do not remove the ground strap connections.

Assemble the strain relief WARNING

The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the

main terminal connection block.

-Failure to do so can result in electrical shock, severe personal injury or death.

Separate Strain Relief

before installation

ENGLISH

Install the power cord as follows:

For power cord installations, Hook the strain relief over the power cord hole (13/8”) located below the rear of drawer body. Insert the power cord through the strain relief and tighten it. (Refer to Figure 7.)

DO NOT install the power cord without a strain relief.

1.Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 8.)

2.Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block.

Make sure that the center wire (white/neutral) is connected to the center lower position of the terminal block.

3.Tighten 3 screws securely into the terminal block.

Do not remove the ground strap connections.

4.Go to page 9.

Assemble the strain relief

to the 1 3/8” opening in

Conduit connection plate

FIGURE 7

3-wire connection

FIGURE 8