System Setup (Cont.)

(Continued from previous page)

8.At the Command > prompt, type info and press Enter. (You can press Enter at any OAT100R command prompt to view current menu, if desired.)

The initial System Information display identifies OAT100R default configuration settings, including the Control Port IP address, the PID configuration, and the output configuration, for example:

OAT100R

CodePlus Off Air Transcoder System

Copyright (c) 2010-2012 LG Electronics U.S.A, Inc. Copyright (c) 2010-2012 Zenith Electronics LLC

SN:

201-12301011

Version

2.1

HW id:

12-19

Ctrl MAC:

00:0C:63:3A:FF:EC

Ctrl IP:

10.166.60.92

Program PIDs:

0x30 - 0x6f

Output:

RF

RF config:

Mode 2, 256-QAM-B, RF: 6 MHz, 5.36 MSps

RF channels:

2 3 4 5

Local time:

Tue Jan 8 14:42:02 CDT 2014

9.Check the Ctrl IP (Control Port IP address) field in the System Information display. By default, the OAT100R uses DHCP; thus, the DHCP server, if configured, assigns an IP address to the OAT100R once the OAT100R successfully connects to the network.

If the Ctrl IP field shows an IP address, the OAT100R is up and running on the network. Continue with step 10.

If the network is configured for DHCP but the Ctrl IP field is blank, refer to “Network Setup” troubleshooting information on page 68.

If the network is not configured for DHCP, you will need to configure a static IP address for the OAT100R. Complete steps 10 to 13 (as required), and then set the OAT100R IP address using the commands indicated in step 14.

10.Check the Output field in the System Information display. If the default value (RF) does not identify the appropriate output type, set the output mode as follows:

a)At the Command > prompt, type setup and press Enter to access the Setup Menu.

b)Use the Setup Menu “omode” command to set the appropriate output mode. See “Set the Output Mode” on page 49 for further information.

11.The next step depends on the output mode:

If you are setting up the system for RF output, continue with step 12.

If you are setting up the system for IP output, go to step 13.

(Continued on next page)