System Setup (Cont.)

(Continued from previous page)

14.(Optional) For remote management purposes, you can set a static IP address for the OAT100R Control Port as follows:

a)If the Command > prompt is on display, type setup and press Enter to access the Setup Menu.

b)At the Setup Command > prompt, type setip and press Enter. The system will display the current network configuration, followed by the Network Configuration Menu.

c)Use the Network Configuration Menu “ip” and “dns” commands to configure the Control Port. See “Configure the Control Port” on page 52 for further information.

Note: Review the New Network Configuration overview carefully before you confirm the Control Port configuration settings. Ensure each of the addresses was entered correctly.

Note: If you change the Control Port configuration, you will be prompted to reset the system. If you intend to modify additional configuration settings during the current session, you may wait until all changes are complete before you reset the system.

15.Once all physical connections to the OAT100R have been made and the Control Port IP address has been assigned or configured, you also have the option to complete the system setup remotely using either the web GUI or the command line interface.

To complete the system setup in the current session (via the Service Port), continue with step 16.

If you wish to complete the setup remotely, reset the system at this time: At either the Command > prompt or the Setup Command > prompt, type reset and press Enter. When you are ready, establish remote communication with the OAT100R, and then continue with step 16. Note that you may use the GUI to perform the configuration steps, if desired. Refer to “Network and Communication Setup” on page 22 for information on establishing remote communication with the OAT100R and/or “Configuration Options via GUI” on pages 23 to 38 for further information on the GUI.

16.(Required only if Pro:Idiom channels are present in the system) Check the Program PIDs

field in the System Information display (if necessary, you can rerun the “info” command from either the Command > or Setup Command > prompt). If the default range (0x30 - 0x6f) is not appropriate for this system, set the PIDs as follows:

a)If the Command > prompt is on display, type setup and press Enter to access the Setup Menu.

b)Use the Setup Menu “pid” command to configure the program PIDs. See “Configure the Program PIDs” on page 50 for further information. Note that PIDs must be specified as hexadecimal numbers.

17.(Optional) If desired, you can identify the location in which the OAT100R is installed. The location description will be displayed as part of the System Information in the command line interface and as part of the System Status and Tuner Information screens in the GUI.

(Continued on next page)

206-4218

19