LG Electronics 32CL40, SAC33601903 Appendix, Data 00 Lock off, Data 01 Lock on, Set ID OK/NGDatax

Models: 55LH40 47LH40 32LH41 42LH40 0910-REV04 47LH41 SAC33601903 47LH55 47CL40 42LH41 32LH40 37LH55 55LH55 42LH55 37LH40 55LH400C 32CL40

1 136
Download 136 pages 54.12 Kb
Page 120
Image 120
11. Sharpness (Command: k k) To adjust screen sharpness.

APPENDIX

APPENDIX

11. Sharpness (Command: k k) To adjust screen sharpness.

You can also adjust sharpness in the PICTURE menu. Transmission [k][k][ ][Set ID][ ][Data][Cr]

Data Min: 00 ~ Max: 64 (*transmit by Hexadecimal code) *Refer to ‘Real data mapping’.

Acknowledgement [k][ ][Set ID][ ][OK/NG][Data][x]

12. OSD Select (Command: k l)

To select OSD (On Screen Display) on/off.

Transmission [k][l][ ][Set ID][ ][Data][Cr]

Data 00: OSD off Data 01: OSD on Acknowledgement [l][ ][Set ID][ ][OK/NG][Data][x]

13. Remote Control LockData 00: Lock offData 01: Lock on Mode (Command: k m)

To lock the remote control and the front panel controls on the set.

Transmission [k][m][ ][Set ID][ ][Data][Cr]

Data 00: Lock off

Data 01: Lock on

 

 

Acknowledgement [m][

][Set ID][ ][OK/NG][Data][x]

 

 

If you’re not using the remote control and front panel controls on the TV, use this mode. When main power is on/off, remote control lock is released.

If Key Lock is on in the standby mode, TV will not turn on by POWER button of remote control and on the TV.

14. Treble (Command: k r) To adjust treble.

You can also adjust treble in the AUDIO menu.

Transmission [k][r][ ][Set ID][ ][Data][Cr]

Data Min: 00 ~ Max: 64 (*transmit by Hexadecimal code) *Refer to ‘Real data mapping’.

Acknowledgement [r][ ][Set ID][ ][OK/NG][Data][x]

15. Bass (Command: k s) To adjust bass.

You can also adjust bass in the AUDIO menu.

Transmission [k][s][ ][Set ID][ ][Data][Cr]

Data Min: 00 ~ Max: 64 (*transmit by Hexadecimal code) *Refer to ‘Real data mapping’.

Acknowledgement [s][ ][Set ID][ ][OK/NG][Data][x]

16. Balance (Command: k t) To adjust balance.

You can also adjust balance in the AUDIO menu. Transmission [k][t][ ][Set ID][ ][Data][Cr]

Data Min: 00 ~ Max: 64 (*transmit by Hexadecimal code) *Refer to ‘Real data mapping’.

Acknowledgement [t][ ][Set ID][ ][OK/NG][Data][x]

17. Color Temperature (Command: k u)

To adjust color temperature.

You can also adjust color temperature in the PICTURE menu.

Transmission [k][u][ ][Set ID][ ][Data][Cr]

Data 00: Medium 01: Cool 02: Warm

Acknowledgement [u][ ][Set ID][ ][OK/NG][Data][x]

18. EnergyManual backgroundManual background Saving (Command: j q)

To control the energy saving function.

Transmission [ j ][q][ ][Set ID][ ][Data][Cr]

Data 00: Energy saving - off

01:Energy saving - Minimum

02:Energy saving - Medium

03:Energy saving - Maximum

04:Energy saving - Auto

05:Energy saving - Screen off

Acknowledgement [q][ ][Set ID][ ][OK/NG][Data][x]

19. Auto Configuration (Command: j u)

To adjust picture position and minimize image shaking automatically. Auto configuration only works in RGB-PC mode.

Transmission [ j ][u][ ][Set ID][ ][Data][Cr]

Data 01: To set

Acknowledgement [u][ ][Set ID][ ][OK/NG][Data][x]

20. Channel Tuning (Command: m a)

To tune channel to following physical/major/minor number.

Transmission [m][a][ ][Set ID][ ][Data00][ ][Data01]

[ ][Data02][ ][Data03][ ][Data04][ ][Data05][Cr]

Digital channels have a Physical, Major, and Minor channel number. The Physical number is the actual digital channel number, the Major is the number that the channel should be mapped to, and the Minor is the sub-channel. Since the ATSC tuner automatically maps the channel to the Major number, the Physical number is not required when sending a command.

Data 00: Physical Channel Number

NTSC air: 02~45, NTSC cable: 01, 0E~7D

ATSC air: 01~45, ATSC cable: 01~87

Data 01 & 02: Major Channel Number

Data 01: High byte

Data 02: Low byte

Two bytes are available for the Major and Minor, nor- mally only the second byte is used.

Data 03 & 04: Minor Channel Number

Not needed for NTSC.

120

Page 120
Image 120
LG Electronics 32CL40, SAC33601903, 37LH55, 37LH40, 37LH41 Appendix, Data 00 Lock off, Data 01 Lock on, Set ID OK/NGDatax