SETTING FLOW & PRESSURE

Oil Flow & Oil Pressure

Working Pressure Range

For a compactor to operate properly it requires a specific oil flow and sufficient oil pressure.

TC51L/FC: 1500-2200 psi @ 8-12 USgpm (102-150 bar) @ (30-45 l/min)

TC51H/FC: 1500-2200 psi @ 12-18 USgpm (102-150 bar) @ (44-68 l/min)

TC71: 1200-2000 psi @ 13-17 USgpm (81-136 bar) @ (49-63 l/min)

TC71FC: 1200-2000 psi @ 13-22 USgpm (81-136 bar) @ (50-83 l/min)

TC80 : 1300-2000 psi @ 20-26 USgpm (88-136 bar) @ (75-97 l/min)

TC91S: 1300-2000 psi @ 20-26 USgpm (88-136 bar) @ (75-97 l/min)

TC151S: 1500-2000 psi @ 25-31 USgpm (102-136 bar) @ (98-121 l/min)

TC151SH: 1100-1600 psi @ 35-43 USgpm (75-109 bar) @ (132-163 l/min)

TC301: 1500-2000 psi @ 35-43 USgpm (102-136 bar) @ (125-163 l/min)

TC301H: 1100-1600 psi @ 50-61 USgpm (75-109 bar) @ (189-231 l/min)

To begin, connect a flow meter into the circuit in place of the compactor. Measure the 'no-load' flow by pressing the compactor fire, which activates the control valve and simulates the compactor working. While still activating the 'compactor' fire, adjust the flow meter putting a load on the circuit. Adjust the flow meter pressure until it falls within the working pressure range:

TC51L/FC: 1500-2200 psi (102-150 bar) TC51H/FC: 1500-2200 psi (102-150 bar)

Carrier

Oil Flow

TC71: 1200-2000 psi (81-136 bar) TC71FC: 1200-2000 psi (81-136 bar)

TC80: 1300-2000 psi (88-136 bar)

 

 

TC91S: 1300-2000 psi (88-136 bar)

 

TC151S: 1500-2000 psi (102-136 bar) TC151SH: 1100-1600 psi (75-109 bar)

 

TC301: 1500-2000 psi (102-136 bar) TC301H: 1100-1600 psi (75-109 bar)

Compactor Owner’s Manual

21