Liebert LM Series TVSS Technical Specification

Liebert LM Series TVSS Technical Specification

Maximum Continuous

 

Operating Voltage (MCOV)

120V 125%, all others 115%

Fault Current Rating (AIC)

200 kAIC

Operating Frequency Range

47 – 63 Hz

Response Time

<0.5 ns

Operating Humidity

0% to 95%

Status Indication

LEDs, Audible Alarm, Dry Contacts

Certifications

UL 1449 & 1283, CUL, NEMA LS1,

Enclosure

ISO 9001:2000

NEMA 12

Warranty

5 Years Parts

Example Part Number: LM250120YARCE 500kA per Phase (250kA per Mode), 120/208V 3-Phase Wye, All Mode,

Rotary Disconnect, LED’s, Alarm,

Counter, & Dual Form C Contacts, NEMA 12 Enclosure

Model # LM __ __ __ __ __ __ __ __ __ __ __

UL 1449 second edition clamping data

Configuration

L-N

L-G

L-L

N-G

120S, 120Y

400

400

700

400

240D

X

700

700

X

346Y

1200

1200

2000

1200

230Y, 277Y

700

700

1500

700

480D

X

1500

1500

X

600D

X

1800

2000

X

Surge Rating

60kA /

060

mode

 

80kA /

080

mode

 

100kA /

100

mode

 

125kA /

125

mode

 

150kA /

150

mode

 

200kA /

200

mode

 

225kA /

 

Source Configuration

1 Phase, L-N, 2W+G

N

 

1 Phase, L-L, 2W+G

L

 

Split Phase, 3W+G

S

 

3 Phase, WYE, 4W+G

Y

 

3 Phase, WYE, 3W+G

X

 

(No Neutral)

 

 

 

3 Phase, Delta, 3W+G

D

 

3 Phase, Delta Hi-leg, 4W+G

H

 

Modes of Protection

All

A

Enclosure

NEMA 12

 

E

 

(Standard)

 

 

 

 

 

NEMA 3R

R

NEMA 4

T

NEMA 4X

X

Life Cycle Surge Testing

10kA, 20kV, IEEE Cat. C3

 

Unit

 

Per Mode

 

Per Phase

 

 

060-080

 

8,000

16,000

 

 

100-150

 

16,000

32,000

 

 

200-250

 

24,000

48,000

 

 

 

 

 

 

 

 

 

E

G

 

C

mode

225

 

 

 

250kA /

 

250

 

mode

 

 

 

 

 

L-G Voltage

120V

120

208V

208

220V

230

230V

230

240V

240

277V

277

480V

480

600V

600

Connection Options

Wire Lug

N

Disconnect

R

 

Monitoring Options

 

 

 

 

Standard Monitoring System,

 

 

S

 

 

 

LEDs, Audible Alarm,

 

 

 

 

 

Dual Form C Contacts

 

 

 

 

 

 

LEDs, Audible Alarm,

 

 

 

 

 

 

Surge Counter,

 

 

C

 

 

 

Dual Form C Contacts

 

 

 

 

 

 

 

 

 

 

 

 

A

D

EMI/RFI Noise Rejection

Single

Frequency

System

Unit

 

Installation

34dB

100kHz

51dB

51dB

1MHz

94dB

54dB

10MHz

114dB

48dB

100MHz

120dB

Job Name ____________________________

Model# ______________________________

Date ________________________________

Qty _________________________________

Quote# ______________________________

FB

Dimensional data in inches and shipping weight in pounds

Unit

Options

A

B

C

D

E

F

G

Wt.

 

 

 

 

 

 

 

 

 

 

LM060

All

16

14

8

16.75

12

0.31

1.35

32

LM080

 

 

 

 

 

 

 

 

 

LM100

All

16

14

8

16.75

12

0.31

1.84

41

LM125

LM150

 

 

 

 

 

 

 

 

 

LM200

 

 

 

 

 

 

 

 

 

LM225

All

20

16

9

21.25

10

0.44

1.84

56

LM250

 

 

 

 

 

 

 

 

 