Model 6511RC User Manual

1 • Introduction

 

 

Temperature

Operating range: 32–104°F (0–40°C)

Altitude

Maximum operating altitude: 15,000 feet (4,752 meters)

Humidity

5 to 95% relative humidity (RH), non-condensing

Physical dimensions

1.75 inches (4.44 cm) height, standard 19-inch (48.26 cm) width, 12-inch (30.48 cm) depth

Weight: 1.55 lbs (0.70 kg)

LED Indicators

LED indicators on the front panel (see figure 5 on page 17) and rear panel (see figure 6 on page 18) display the status of Matrix Switch system resources. The front-panel LEDs are described in table 3. The rear-panel LEDs are described in table 4 on page 28.

 

 

 

Table 3. Front-panel LED indicators

 

 

 

 

LED

Color

Status

Meaning

 

 

 

 

POWER

Green

On solid

Power is being applied.

 

 

Flashing

The 6511RC has detected a power failure on a power bus.

 

 

 

 

 

 

Off

No input power is being applied.

CPU FAIL

Red

On solid

CPU is unable to load the software from FLASH to RAM for operation.

 

 

 

 

 

 

Off

The CPU is operating normally.

ALARM

Yellow

On solid

A minor alarm condition has been detected.

 

 

 

 

 

 

Flashing

A major alarm condition has been detected.

 

 

Off

The Model 6511RC system is operating normally.

SYSTEM

Green

Flashing

The Model 6511RC system is operating normally.

 

 

Off

The Model 6511RCsystem is not functioning properly.

 

 

 

 

ENET(NODE)

Green

On solid

Indicates there is Ethernet frame activity on one or more of the 6511RC’s Ethernet inter-

 

 

 

faces, including the two rear-panel 10/100/1000 ports, the front -panel 10/100 port,

 

 

 

and the packet--switched PICMG 2.16 bus.

 

 

Off

Indicates NO Ethernet frame activity detected on any of the 6511RC’s Ethernet interfaces,

 

 

 

including the PICMG 2.16 bus.

CLK SOURCE

Green

On solid

The 6511RC is defined as the Primary (master) clock source for the H.100 bus

 

 

Flashing

The 6511RC is defined as the Secondary (alternate master) clock source.

 

 

 

 

 

 

Off

The 6511RC is defined as a slave, deriving its clock from the H.110 Bus.

CLK ERROR

Yellow

On solid

Primary Master Clock source has been lost and the 6511RC is using the secondary

 

 

 

source for its clock.

 

 

 

 

 

 

Flashing

Master Clock source and the Secondary Clock source have been lost and the 6511RC

 

 

 

is using its internal crystal for its clock.

 

 

Off

No clock errors currently detected.

 

 

 

 

Hardware overview

27

Page 27
Image 27
Patton electronic 6511RC user manual Temperature, Altitude, Humidity, Physical dimensions, LED Indicators