3 • Configuring the Matrix Switch for operation

Model 6511RC User Manual

 

 

Example 3

Map E1 Port 7 received, timeslots 1-32 to H.110 Port 4 timeslots 1-32.

Map E1 Port 7 transmitted, timeslots 1-32 from H.110 Port 4 timeslots 33-64.

Solution:

1.Under E1 Number, select port7(7) from the drop-down menu (see figure 52).

2.Under E1 Slots, enter 1-32in the text box.

3.For toH110(5), under H.110 Number, select port4(4) from the drop-down menu.

4.For toH110(5), under H.110 slots, enter 1-32in the text box.

5.For fromH110(5), under H.110 Number, select port4(4) from the drop-down menu.

6.For fromH110(5), under H.110 slots, enter 33-64in the text box.

Figure 52. Define a Mapping table for example 3

7.Click the Define button.

8.Verify your new mapping appears in the Defined Mappings table (see figure 53).

Figure 53. Defined Mappings table for example 3

9.Examine the new mapping to verify that it was entered and recorded correctly. You have completed the configuration for example 3.

68

Using a browser to complete Model 6511RC configuration

Page 68
Image 68
Patton electronic 6511RC user manual Solution