Model 6511RC User Manual | 5 • Troubleshooting and maintenance |
|
|
connections. The data passes through the H.110 framer, then traverses the SDH framer where it loops back, passing through the H.110 framer again. The data leaves the Matrix switch through its
The terminal loop affects only those DS0s that are mapped from the H.110 bus to the
The terminal loop exercises the physical and logical connections between the Matrix Switch and the other ForeFront modules connected to the same H.110 bus (its SDH terminals). You can use the terminal loop to test and troubleshoot the DS0 mappings you have defined while simultaneously testing H.110 bus connectiv- ity with other ForeFront modules via the chassis
To activate the Terminal Loop test mode:
1.On the configuration menu, click the SDH hyperlink to display the SDH Overview page.
2.At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration page (see figure 64).
3.Scroll down to the Loopback parameter in the SDH Interface Configuration table.
4.From the
5.Click the first Submit button located just below the SDH Interface Parameters table.
Figure 64. SDH Configuration page with sonetTerminalLoop(2) selected
To deactivate the terminal loop test mode, from the LoopBack parameter
Matrix Switch test tools | 89 |