Liebherr 36 Ventilation Requirements CS 1601, CS 1650, SBS 32S0, Kitchen Cabinet Airflow, A B C

Models: 60 36 30

1 20
Download 20 pages 13.46 Kb
Page 16
Image 16
Ventilation Requirements CS 1601, CS 1650, SBS 32S0

Freestanding/Semi Built In Models

CS 1601, 1650 - SBS 32S0

Ventilation Requirements CS 1601, CS 1650, SBS 32S0

This type of cabinet must be carefully constructed using the correct dimensions and it must provide suitable ventilation to ensure proper appliance operation.

Kitchen Cabinet Airflow

1.The following ventilation dimensions must be observed:

There must be a ventilation space at least 31 in.² (200 cm²) at the airflow inlet (1) and at the airflow outlet (2). The 30" and 60" models are equipped with a rolling base, which is already providing you with the bottom airflow inlet require- ments.

The top ventilation space can be directed in one of the fol- lowing ways:

A)Directly over the appliance (2) with either an optional factory air vent or custom made one using the template sup- plied with the unit.

B)Above the cabinet and below the ceiling (3).

C)Through a vent installed in a soffit (4).

AKitchen Cabinet Airflow

B

C

B - Side view
Cabinet
Refrigerator

The refrigerator is designed to allow proper air flow when the appliance is installed up against the wall.

A minimum space of 1 1/2" is required when a cabinet is built above.