General Remarks

IV. Area Requirements

Verify the following:

Floors can support refrigerator’s weight plus approxi- mately 1200 pounds (544 kg) of food weight. Not

all Liebherr products are designed for 1200 pounds (544 kg) of food. Some units are smaller and total weights may vary.

Finished kitchen floor height is level. Refrigerator must be shimmed to the floor level, or levelled, to make sure, air vents are not obstructed.

Remove anything attached to the rear or side walls that can obstruct refrigerator opening.

Cutout dimensions are accurate.

Electrical outlet is in correct location.

Do not install this unit next to any other refrigerator or freezer except another Liebherr model. Liebherr models are designed to allow side by side installation. They are equipped with a heating system to eliminate condensa- tion when units are installed side by side. Installing this unit next to any other refrigerator or freezer can cause condensation or cause damage to the Liebherr unit.

To protect the refrigerator from possible damage, allow the appliance to stand 1/2 to 1 hour in place before turning the electricity on. This allows the refrigerant and system lubrication to reach equilibrium.

Blocking For Safety

The anti-tip bracket must be installed to prevent the unit from tipping after it is installed. Refer to chapter "Block- ing For Safety" in the installation instructions.

V. Safety Regulations

The appliance complies with UL250 and CAN/CSA-C 22,2 No. 63 and is designed to cool, freeze, store food as well as make ice (if equipped). It is designed as a household appliance. If used commercially, the relevant regulations on commercial use must be observed.

The appliance is set to operate within specific ambient temperature limits according to its climate rating. These temperature limits should not be exceeded. The cor- rect climate rating for your appliance is indicated on the model plate.

This is explained as follows:

Climate

Set for Ambient Temperatures of

Rating

 

 

 

SN

50°F to 90°F (10°C to 32°C)

N

61°F to 90°F (16°C to 32°C)

ST

61°F to 100°F (16°C to 38°C)

T

61°F to 109°F (16°C to 43°C)

SN-ST

50°F to 100°F (10°C to 38°C)

SN-T

50°F to 109°F (10°C to 43°C)

 

 

- The refrigerant circuit has been tested for leaks.

Page 9
Image 9
Liebherr 30, 36, 60 manual IV. Area Requirements, Safety Regulations