Setting up
•Avoid positioning the appliance in direct sunlight or near cookers, radiators and similar sources of heat.
•The floor on which the appliance stands should be horizontal and level.
•The ventilation grilles should not be obstructed. Always ensure that there is good ventilation and that the outward flowing air is able to escape.
•Standard EN 378 specifies that the room in which you install your appliance must have a volume of 1 m³ per 8 g of R 600a refrigerant used in the appliance, so as to avoid the formation of inflammable gas/air mixtures in the room where the appliance is located in the event of a leak in the refrigerant circuit. The quantity of refrigerant used in your appliance is indicated on the type plate on the inside of the appliance.
•Do not connect the appliance to the supply with other equipment using an extension cable - risk of overheating.
Connecting to the mains
Power supply (AC) and voltage at the operating point must comply with the details on the type plate, which is located on the inside left of the appliance, next to the vegetable bins. The socket must be fused with a 10 A fuse or higher, it must be away from the rear of the appliance and must be easily accessible.
Connect the appliance with a properly earthed fused plug and socket only.
Appliance venting
The required air flow is directed through the plinth.
It is important to use the provided ventilation grille for the ventila- tion opening.
This opening must not be covered.
Appliance dimensions
A = 76 mm
B = 2027 mm
C = 910 mm
D = 610 mm
E = 1556 mm
F = 943 mm
Screw the supplied securing plates on the left and on the right of the appliance using 3.9 x 11 screws.
12