Life Fitness Sport, Essential, and Bally's Consumer Treadmills
Bushing Replacement | Service Kit: |
•Bushing Spacer #HEA50720 (2)
•Track Slider #HEA50714 (2)
•Connection Tube Bushing #HEA50708 (2)
•Tie Wraps (2)
The nitrogen gas shocks aid only in folding the unit. These shocks must be removed with the unit on its side and in the folded position.
1.Pull the Release Handle, which is on the left rear of the unit, and unfold the unit.
2.If the unit power cord is unplugged, then plug in the power cord, and then turn ON the unit.
3.At the Control Console, set the unit elevation to zero.
4.With the elevation at zero, shut OFF the unit, and then unplug the AC power cord from the wall and the unit and set it aside.
5.Remove four Phillips screws from the motor cover and lift off the motor cover.
6.Fold the unit back up.
IMPORTANT: Care must be taken to avoid damaging the unit or the floor before proceeding to the next step.
7.With sufficient protective covering on the floor and the unit in the folded position, tilt the unit over on its right side so that the Release Handle is
exposed and easily accessible.
NOTE: THE UNIT MUST BE IN THE
FOLDED POSITION WITH SHOCKS
FULLY EXTENDED BEFORE
ATTEMPTING TO REMOVE SHOCKS.
8.The shocks aid only in ease of folding the unit. These shocks must be removed with the unit on its side in the folded position. Before removing the shocks, note that the rod end connects to the pivoting brace while the cylinder end connects to the main frame. Remove the nuts (13mm) at both ends of the shock and lift off the shock from the threaded mounting posts. It may be necessary to apply some additional folding pressure to the unit to release each shock from its mountings.
9. With the shocks removed and theHardware Shocks Hardware unit still on its right side, pull the
Release Handle and unfold the unit, and then upright the unit.
1
ASSY INSTRUCTIONS, KIT, FT BUSHING 77650901