Lightolier 0890 instruction sheet REMODELER Kl~, Installation Procedure For Calculite@, IS A400RM

Models: 0890

1 2
Download 2 pages 47.5 Kb
Page 1
Image 1
REMODELER Kl~

(

1

INSTRUCTION SHEET NO.

REMODELER Kl~

IS:A400RM

INSTALLATION PROCEDURE FOR CALCULITE@

 

 

 

0890

Page 1 M 2

READ AND UNDER=AND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE.

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before ii%tallation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference

WARNING—(RISK OF FIRE) DO NOTINWALLINSULATIONWITHIN 3 INCHESOF FIXTURE SIDES OR

WIRING COMPARTMENT, NOR ABOVE FIXTURE IN SUCH A MANNER TO ENTRAP HEAT.

EXISllNG CONSTRUCllON

“.. .,.,.

.,, t.

,, ‘

e

Ca

8

10e

%pp

FIG. A

FIG. B

FIG. C

FIG. D

FIG. E

FIG. F

L CUT OPENING

Il. WIRE-IN

Ill. ATTACH J-BOX

IV. AITACH

V. SNAPON

VI. PUSH-UP

 

 

 

MOUNTING RING

 

 

.—

THERMAL

PROTECTOR

L CUT OPENING (Fig. A)

Use MOUNTING RING provided as a template to

7

 

cut a hole in the ceiling. Use inside diameter to

 

SCribe hole.

 

II.WIRE-IN (Fig. B)

Wire to suppl~leads. (For Cable, use built-in Cable Clamp in J-Box.) White fixture lead to neutral supply lead. Black fixture lead to hot (120V) supply lead. Bare fixture wire to supply ground. Use wirenuts (local hardware item). Place all electrical connections in the J-BOX. Attach J-BOX COVER onto J-BOX.

~J. BOX PLATE

LONG LEG

- RAISED BUMP

Ill. AITACH J-BOX (Fig. C & G)

1.Attach J-BOX PLATE to ceiling by pushing NAIL TAB on J-BOX PiATE into ceiling, Fig. G.

2.Push LONG LEG of NAIL CLIPS (supplied in parts bag) into RAISED BUMP of J-BOX PIATE and SHORT LEG into ceiling, Fig. G.

3.Make sure that the J-BOX PLATE is securely

attached to the

ceiling

and the J-BOX is in the

FiG. G

 

position shown

in Fig.

G.

 

Page 1
Image 1
Lightolier 0890 instruction sheet REMODELER Kl~, Installation Procedure For Calculite@, L CUT OPENING Fig. A, IS A400RM