Performance Recessed CFL Downlighting 1001HL
Page 2 of 2 5" Aperture Horizontal Wet Location, Compact Fluor., Performance Series, Reflector Trim
26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS
150
300
450
600
60˚
1
SC = 1.1 | 30˚ |
|
CERTIFIED TEST REPORT NO. 3345FR COMPUTED BY LSI PROGRAM
CANDLEPOWER SUMMARY |
| ZONAL LUMEN SUMMARY | |||
Angle | 0° CP | Zone | Lumens | ||
0 | 486 |
| 47.19 | ||
5 | 486 |
| 10 | 133.79 | |
10 | 476 |
| 20 | 178.34 | |
15 | 457 |
| 30 | 167.29 | |
20 | 427 |
| 40 | 137.02 | |
25 | 373 |
| 50 | 60.2 | |
30 | 312 |
| 6.14 | ||
35 | 262 |
| 70 | 1.07 | |
40 | 231 |
| 80 | .34 | |
45 | 208 |
| 0 | ||
50 | 122 |
| 0 | ||
55 | 66 |
| 110 | 0 | |
60 | 19 |
| 120 | 0 | |
65 | 4 |
| 0 | ||
70 | 2 |
| 140 | 0 | |
75 | 1 |
| 150 | 0 | |
80 | 1 |
| 0 | ||
85 | 0 |
| 170 | 0 | |
|
|
|
|
900
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
| ||||||
Ceiling |
| 80% |
| 70% | 50% | 30% | 0 | ||||||
Wall |
| 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 | |
RCR |
| Zonal Cavity Method - Effective Floor Reflectance = 20% | |||||||||||
| 0 | 51 | 51 | 51 | 51 | 50 | 50 | 48 | 48 | 46 | 46 | 43 | |
| 1 | 48 | 47 | 45 | 44 | 46 | 44 | 44 | 42 | 42 | 41 | 39 | |
Ratio | 2 | 45 | 43 | 41 | 39 | 42 | 38 | 40 | 38 | 39 | 37 | 35 | |
3 | 42 | 39 | 36 | 34 | 38 | 34 | 37 | 34 | 36 | 33 | 32 | ||
Cavity | 4 | 39 | 36 | 33 | 31 | 35 | 30 | 34 | 30 | 33 | 30 | 29 | |
5 | 37 | 33 | 30 | 27 | 32 | 27 | 31 | 27 | 31 | 27 | 26 | ||
| |||||||||||||
Room | 6 | 35 | 30 | 27 | 25 | 30 | 25 | 29 | 25 | 28 | 24 | 23 | |
7 | 32 | 28 | 25 | 23 | 27 | 23 | 27 | 22 | 26 | 22 | 21 | ||
| 8 | 31 | 26 | 23 | 21 | 25 | 21 | 25 | 20 | 24 | 20 | 20 | |
| 9 | 29 | 24 | 21 | 19 | 24 | 19 | 23 | 19 | 23 | 19 | 18 | |
10 | 27 | 22 | 19 | 18 | 22 | 19 | 22 | 17 | 21 | 17 | 17 |
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS
150
300
450
600
|
|
|
| CANDLEPOWER SUMMARY |
| ZONAL LUMEN SUMMARY | ||
|
|
|
| Angle | 0° CP | Zone | Lumens | |
|
|
|
| 0 | 562 |
| 51.18 | |
|
|
|
| 5 | 545 |
| 133.02 | |
|
|
|
| 10 | 514 |
| 167 | |
|
| 60˚ | 15 | 477 |
| 150.81 | ||
|
| 20 | 423 |
| 17.04 | |||
|
|
|
|
| ||||
|
|
|
| 25 | 362 |
| 60.58 | |
|
|
|
| 30 | 302 |
| 8.93 | |
|
|
|
| 35 | 248 |
| 1.06 | |
| 1 |
|
| 40 | 203 |
| .14 | |
|
|
|
| 45 | 165 |
| 0 | |
|
|
|
| 50 | 125 |
| 0 | |
|
|
|
| 55 | 68 |
| 0 | |
|
|
|
| 60 | 27 |
| 0 | |
|
|
|
| 65 | 6 |
| 0 | |
SC = 0.92 | 30˚ | 70 | 1 |
| 0 | |||
|
|
| 75 | 1 |
| 0 | ||
CERTIFIED TEST REPORT NO. 3344FR | 80 | 1 |
| 0 | ||||
85 | 0 |
| 0 | |||||
COMPUTED BY LSI PROGRAM |
| |||||||
90 | 0 |
|
|
| ||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
| ||||||
Ceiling |
| 80% |
| 70% | 50% | 30% | 0 | ||||||
Wall |
| 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 | |
RCR |
| Zonal Cavity Method - Effective Floor Reflectance = 20% | |||||||||||
| 0 | 48 | 48 | 48 | 48 | 47 | 47 | 45 | 45 | 43 | 43 | 40 | |
| 1 | 45 | 44 | 43 | 42 | 43 | 41 | 42 | 40 | 40 | 39 | 37 | |
Ratio | 2 | 43 | 40 | 38 | 37 | 40 | 36 | 38 | 36 | 37 | 35 | 33 | |
3 | 40 | 37 | 34 | 33 | 36 | 32 | 35 | 32 | 34 | 31 | 30 | ||
| |||||||||||||
Cavity | 4 | 37 | 34 | 31 | 29 | 33 | 31 | 32 | 29 | 31 | 28 | 27 | |
5 | 35 | 31 | 28 | 26 | 31 | 26 | 30 | 29 | 27 | 26 | 25 | ||
| |||||||||||||
Room | 6 | 33 | 29 | 26 | 24 | 32 | 24 | 28 | 23 | 27 | 23 | 22 | |
7 | 31 | 26 | 24 | 22 | 26 | 22 | 26 | 21 | 25 | 21 | 21 | ||
| 8 | 29 | 25 | 22 | 20 | 24 | 20 | 24 | 20 | 23 | 20 | 19 | |
| 9 | 27 | 23 | 20 | 18 | 23 | 18 | 22 | 18 | 22 | 18 | 17 | |
10 | 26 | 21 | 19 | 17 | 21 | 17 | 21 | 17 | 21 | 17 | 16 |
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
26W TRIPLE TUBE LAMP, LUMEN RATING = 1710 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS
100
200
300
400
60˚
1
30˚
SC = 1.1
CERTIFIED TEST REPORT NO. 3346FR COMPUTED BY LSI PROGRAM
CANDLEPOWER SUMMARY |
| ZONAL LUMEN SUMMARY | ||||
Angle | 0° CP | 90° CP | Zone | Lumens | ||
0 | 369 | 369 |
|
| 34.84 | |
5 | 365 | 368 |
| 98.51 | ||
10 | 360 | 362 |
| 141.87 | ||
15 | 349 | 351 |
| 153.58 | ||
20 | 332 | 334 |
| 129 | ||
25 | 309 | 310 |
| 60.3 | ||
30 | 280 | 281 |
| 7.52 | ||
35 | 247 | 248 |
| .43 | ||
40 | 208 | 208 |
| 0 | ||
45 | 168 | 167 |
| 90 | 0 | |
50 | 124 | 123 |
| 0 | ||
55 | 62 | 62 |
| 0 | ||
60 | 22 | 24 |
| 120 | 0 | |
65 | 4 | 5 |
| 0 | ||
70 | 1 | 1 |
| 140 | 0 | |
75 | 1 | 0 |
| 150 | 0 | |
80 | 0 | 0 |
| 0 | ||
85 | 0 | 0 |
| 170 | 0 | |
90 | 0 | 0 |
|
|
|
|
|
|
|
|
|
|
ZONAL LUMENS AND PERCENTAGES |
|
|
|
|
|
| COEFFICIENTS OF UTILIZATION |
|
|
| ||||||||
Zone | Lumens | %Lamp | %Fixt |
| Ceiling |
| 80% |
| 70% | 50% | 30% | 0 | ||||||
275.21 | 16.1 | 44 |
| Wall |
| 70 | 50 | 30 | 10 | 50 | 10 | 50 | 10 | 50 | 10 | 0 | ||
| RCR |
| Zonal Cavity Method - Effective Floor Reflectance = 20% | |||||||||||||||
428.79 | 25.1 | 68.5 |
|
| ||||||||||||||
|
|
| 0 | 44 | 44 | 44 | 44 | 43 | 43 | 41 | 41 | 39 | 39 | 37 | ||||
618.1 | 36.1 | 98.7 |
|
|
| |||||||||||||
|
|
| 1 | 41 | 40 | 39 | 38 | 39 | 37 | 38 | 36 | 36 | 35 | 33 | ||||
626.05 | 36.6 | 100 |
|
|
| |||||||||||||
| Ratio | 2 | 38 | 36 | 34 | 33 | 36 | 33 | 34 | 32 | 33 | 31 | 30 | |||||
0 | 0 | 0 |
| 3 | 36 | 33 | 31 | 29 | 32 | 29 | 31 | 28 | 30 | 28 | 27 | |||
0 | 0 | 0 |
| Cavity | 4 | 33 | 30 | 27 | 26 | 30 | 25 | 29 | 25 | 28 | 25 | 24 | ||
0 | 0 | 0 |
| 5 | 31 | 27 | 25 | 23 | 27 | 23 | 26 | 22 | 26 | 22 | 21 | |||
|
|
| ||||||||||||||||
0 | 0 | 0 |
| Room | 6 | 29 | 25 | 22 | 20 | 25 | 20 | 24 | 20 | 24 | 20 | 19 | ||
626.05 | 36.6 | 100 |
| 7 | 27 | 23 | 20 | 18 | 23 | 18 | 22 | 18 | 22 | 18 | 17 | |||
|
|
| 8 | 25 | 21 | 19 | 17 | 21 | 17 | 21 | 17 | 20 | 17 | 16 | ||||
|
|
|
|
|
|
| ||||||||||||
| ** Efficiency = 36.6% ** |
|
|
|
| 9 | 24 | 20 | 17 | 15 | 19 | 15 | 19 | 15 | 19 | 15 | 14 | |
|
|
|
|
|
| 10 | 23 | 18 | 16 | 14 | 18 | 14 | 18 | 14 | 17 | 14 | 13 | |
|
|
|
|
| Determined In Accordance With Current IES Published Procedures | |||||||||||||
|
|
|
|
|
|
|
|
|
| Luminaire Input Watts = 33.0 |
|
|
|
Job Information | Type: |
|
|
631 Airport Road, Fall River, MA 02720 • (508)
Lightolier is a Philips group brand