READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:1104ICX

B1204 Page 1 of 2

INSTALLATION PROCEDURE FOR HIGH WATTAGE INSULATED CEILING

FRAME-IN KITS 1004ICX, 1004ICXN, 1104ICX, 1104ICXN,

NEW CONSTRUCTION

NOTE: I.C. Frame-In Kit may be used in direct contact with insulation.

Fig. A

Fig. B

Fig. C

Fig. D

Fig. E

Fig. F

Frame-In

Wire-In

Swing-Up

Close-In

Snap-On

Push-Up

WARNING: USE ONLY WITH LIGHTOLIER REFLECTOR TRIMS MARKED WITH I.C. LAMPING INFORMATION. USE OF OTHER MANUFACTURERS’ TRIMS VOIDS THE UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD

1.FRAME-IN (Fig. A)

Locate fixture along joist and line up bottom edge of HINGED MOUNTING BAR with the bottom of joist and fasten in place.

5 1/4” 1004ICX

5 5/8” 1104ICX

CENTER LINE OF

APERTURE OPENING

6 3/8” 1004ICX 6” 1104ICX

Note: Integral nail version available

HINGED MOUNTING BAR

BEND AT HOLE

TAB

 

BEND AT TAB

For suspended ceilings:

Rotate HINGED BAR ENDS to position shown and fully extend bars.

Crimp bottom of edge of CHANNEL to prevent rotation of HINGED BAR ENDS.

Bend NON-HINGED end of mounting bar at featured hole location and extend out.

Position notched area of MOUNTING BARS onto T-BAR and lock by bending TAB underneath T-BAR BEAD as shown.

For suspended ceiling, make certain that bottom of Mounting Frame is no higher than 1” above ceiling line.

HINGED BAR ENDS

T-BAR

CHANNEL

FOR JOIST SPACING LESS THAN 16” ON CENTER (TO 12” ON CENTER):

MOUNTING BAR CHANNELS can be shortened and used as nailing legs in tight spaces. Simply remove INNER BAR from holed CHANNEL, bend CHANNEL at appropriate point and use extra screw to secure it to the joist. (Fig. G)

TAB

Fig. G