Lightolier IS:1104IC WIRE-INFig. B, SWING-UPFig. C, CLOSE-INFig. D, AIRSEAL INSTALLATION optional

Models: IS:1104IC 1104IC 1104SIC

1 2
Download 2 pages 30.18 Kb
Page 2
Image 2
Page 2 of 2

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:1104IC

E1204

Page 2 of 2

2. WIRE-IN (Fig. B)

Open hinged J-BOX COVER fully to its locked position (lift slightly to unlock).

Open hinged KNOCK OUT to allow NON-METALLIC CABLE to enter JUNCTION BOX. Push CABLE through CLAMP.

NOTE: Wiring and connections must not be placed in JUNCTION BOX in a manner which will interfere with the CLAMPS action to provide strain relief.

Wire to SUPPLY LEADS. WHITE FIXTURE LEAD to NEUTRAL SUP- PLY LEAD. BLACK FIXTURE LEAD to HOT (120V) SUPPLY LEAD. BARE FIXTURE WIRE to SUPPLY GROUND. Use wirenuts (local hardware item). Place all electrical connections in the

J-BOX and close the J-BOX COVER.

3.SWING-UP (Fig. C)

Extend MOUNTING BAR to reach opposite joist and fasten in place. Adjust to desired position along MOUNTING BAR and lock in place.

4.CLOSE-IN (Fig. D)

Install plasterboard or other dry type ceiling. Hole in board

can be cut either on the floor or after the board is secured to the ceiling using HOUSING opening as cutting guide. HOUSING is secured by 3 screws which allow adjustment for variable ceiling thicknesses.

5.AIRSEAL® INSTALLATION (optional)

Option 1: Install LAS56 Flange Gasket Kit (available separately).

Option 2: Install a bead of silicone caulking compound between the ceiling opening and edge of HOUSING. Housings are tested in accordance with ASTM E 283 (max 2 cfm @ 75 pa) and comply with WSEC & MEC when installed as instructed.

NOTE: If factory installed tape or knockouts are removed from vertical adjustment slots in housing wall LAS56 Flange Gasket Kit must be used (available separately).

NON-METALLIC

SHEATHED CABLE J-BOX COVER (12 OR 14 GAUGE ONLY)

HINGED KNOCK OUT

CABLE CLAMP

JUNCTION BOX

SQUEEZE CLIP

Squeeze to adjust, release to lock

MOUNTING BAR

DEFORM MATERIAL HERE

FOR ADDITIONAL LOCK

FOR TIGHT SPACES: MOUNTING BAR CHANNELS can be shortened and used as nailing legs in tight spaces.

6.SNAP-ON (Fig. F)

Important - Insert SOCKET CUP in neck

of REFLECTOR making sure SPRING TABS

fully engage into SLOTS in REFLECTOR. }

7.PUSH-UP (Fig. E)

Push REFLECTOR TRIM straight up until it is tight against ceiling.

SEE SEPARATE REFLECTOR TRIM INSTRUCTION SHEETS

Simply remove INNER BAR

from holed CHANNEL, bend CHANNEL at appropriate point and use extra screw to secure it to the joist. (Fig. D)

SOCKET CUP

To remove TRIM:

Turn off power to fixture

Remove lamp

Squeeze REFLECTOR SPRING from inside until the TRIM disengages.

To retrieve SOCKET CUP, pull on one of the SOCKET SPRING LEGS to disengage.