Architectural Decorative 4K28
Page 2 of 2 | Pendalux Contemporary 28” Diameter Body |
Features
1.Diffusing Reflector: White translucent acrylic, 3/16” thick.
2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3.Chassis: Steel 20 gauge,
4.Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia. fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.
5.Cables: Reflector Bowl is suspended from a central point on three 1/16” stainless steel cables.
6.Lampholder:
7.Flange Trim: Steel 20 gauge, Plated or Painted Finish.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
|
| General Electric |
|
| Osram/Sylvania | Philips | |||||||
|
| 26W Triple Tube |
| ||||||||||
|
| F26TBX/*/A/4P |
|
| CF26DT/E/IN/* |
|
|
|
|
|
| ||
|
|
|
|
|
| ||||||||
| 32W Triple Tube |
| |||||||||||
|
| F32TBX/*/A/4P |
|
|
| CF32DT/E/IN/* |
|
|
|
| |||
|
|
|
|
|
| ||||||||
42W Triple Tube |
| ||||||||||||
|
| F42QBK/*/A/4P |
|
| CF42DT/E/IN/* |
|
| ||||||
|
|
|
|
| |||||||||
*Manufacturers’ color temperature designation. |
|
Electrical
Ballast: Electronic,
Universal Voltage 120/277V,
4 Lamps |
| 26 Watt |
| 32Watt |
|
| 42Watt |
| ||||
Voltage |
| 120V |
| 277V |
| 120V |
| 277V |
| 120V |
| 277V |
Total Input Watts |
| 110 |
| 110 |
| 140 |
| 140 |
| 186 |
| 186 |
Max. Line Current (amps) |
| 1.11 |
| 0.48 |
| 1.40 |
| 0.60 |
| 0.60 |
| 0.80 |
Power Factor |
| >0.98 |
| >0.98 |
| >0.98 |
| >0.98 |
| >0.99 |
| >0.99 |
Ballast Factor |
| 1.02 |
| 1.02 |
| 0.96 |
| 0.96 |
| 0.95 |
| 0.95 |
|
|
|
|
|
|
THD<10% Minimum Starting Temperature
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus listed suitable for damp locations.
Application Data
28 Inch Diameter |
|
|
|
| |
30’ x 30’ x 10’ Space |
|
|
| ||
Luminaire |
| Spacing: 10’ x 10’ |
| ||
|
|
| Susp. Dist. 28” |
| |
4 Lamps |
| 26W |
| 32W | 42W |
|
| TTT |
| TTT | TTT |
Illum. (FC) |
| 26 |
| 35 | 45 |
Maint. |
|
|
|
|
|
Lum. |
| 15/1 |
| 15/1 | 14/1 |
Ratio |
|
|
|
|
|
Watts/ |
| 1.10 |
| 1.36 | 1.86 |
Sq. Ft. |
|
|
|
|
|
Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.
CERTIFIED TEST REPORT NO. 4K28442A
COMPUTED BY LSI PROGRAM
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4K28442ASBU, 28” DIFFUSER
|
|
| CANDLEPOWER SUMMARY |
| ||||
|
| ANGLE MEAN CP LUMENS | ANGLE MEAN CP LUMENS | |||||
|
| 0 | 417 |
|
| 90 | 40 |
|
|
| 5 | 420 | 40 |
| 95 | 165 | 227 |
|
| 10 | 415 |
|
| 100 | 461 |
|
|
| 15 | 408 | 115 |
| 105 | 751 | 777 |
|
| 20 | 395 |
|
| 110 | 975 |
|
|
| 25 | 380 | 176 |
| 115 | 1171 | 1159 |
|
| 30 | 361 |
|
| 120 | 1351 |
|
|
| 35 | 337 | 212 |
| 125 | 1516 | 1349 |
|
| 40 | 312 |
|
| 130 | 1633 |
|
|
| 45 | 286 | 221 |
| 135 | 1706 | 1317 |
|
| 50 | 257 |
|
| 140 | 1753 |
|
|
| 55 | 224 | 201 |
| 145 | 1803 | 1129 |
|
| 60 | 190 |
|
| 150 | 1826 |
|
|
| 65 | 157 | 155 |
| 155 | 1817 | 838 |
|
| 70 | 123 |
|
| 160 | 1779 |
|
|
| 75 | 90 | 97 |
| 165 | 1691 | 473 |
|
| 80 | 62 |
|
| 170 | 1506 |
|
|
| 85 | 39 | 49 |
| 175 | 1349 | 134 |
|
| 90 | 40 |
|
| 180 | 1428 |
|
|
|
| ZONAL LUMENS AND PERCENTAGES |
| ||||
|
|
|
| |||||
DATE: DEC. 20, 2000 |
|
|
|
|
|
|
|
|
PREPARED FOR: |
| ZONE | LUMENS | % LAMP | %LUMINAIRE | |||
LIGHTOLIER, FALL RIVER, MA | 358 |
| 2.61 | 3.20 |
| |||
| 588 |
| 4.29 | 5.28 |
| |||
|
|
| ||||||
| 1046 |
| 7.80 | 9.59 |
| |||
| 1373 |
| 10.73 | 15.84 |
| |||
| 784 |
| 6.14 | 9.06 |
| |||
| 327 |
| 2.55 | 3.76 |
| |||
| 8040 |
| 62.81 | 92.76 |
| |||
| 9412 |
| 73.54 | 100.00 |
| |||
|
|
| ** EFFICIENCY =73.5% ** |
|
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
|
| 80 |
|
| 70 |
|
| 50 |
|
| 30 |
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
| 1 | .58 .56 .53 | .51 .49 .46 | .38 .36 .35 | .25 .25 .24 | .14 .14 .13 | .08 | ||||||||||
| 2 | .51 .47 .41 | .44 .41 .38 | .33 .31 .28 | .22 .21 .20 | .12 .12 .11 | .07 | ||||||||||
RATIO | 3 | .49 .40 .36 | .39 .35 .32 | .29 .27 .24 | .20 .18 .17 | .11 .10 .10 | .06 | ||||||||||
4 | .39 .34 .31 | .35 .30 .27 | .26 .23 .21 | .16 .16 .14 | .10 .09 .08 | .05 | |||||||||||
CAVITY | 5 | .34 .30 .26 | .31 .26 .23 | .23 .20 .18 | .16 .14 .12 | .09 .08 .07 | .04 | ||||||||||
| |||||||||||||||||
ROOM | 6 | .31 .26 .22 | .27 .23 .20 | .20 .17 .15 | .14 .12 .11 | .08 .07 .06 | .04 | ||||||||||
8 | .25 .20 .17 | .22 .18 .15 | .17 .14 .11 | .11 .09 .08 | .06 .05 .05 | .03 | |||||||||||
| 7 | .28 .23 .19 | .24 .20 .17 | .18 .15 .13 | .13 .11 .09 | .07 .06 .05 | .03 | ||||||||||
| 9 | .23 .18 .14 | .20 .16 .13 | .15 .12 .10 | .10 .08 | .07 | .06 .05 .04 | .02 | |||||||||
| 10 | .20 .16 .13 | .18 .14 .11 | .14 .11 .09 | .09 .08 | .06 | .05 .04 .04 | .02 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Job Information | Type: |
|
|
Lightolier a Genlyte company |
| www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 Genlyte Group LLC • C0605