Architectural Decorative 4R28
Page 2 of 2 | Pendalux Traditional 28" Diameter Body |
Features
1.Diffusing Reflector: White translucent acrylic, 3/16” thick.
2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3.Chassis: Steel 20 gauge,
4.Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia. fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.
5.Rods: Reflector Bowl is suspended from a central point on three 3/16” steel tubes.
6.Lampholder:
7.Flange Trim: Steel 20 gauge, Plated or Painted finish.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
General Electric | Osram/Sylvania | Philips |
26W Triple Tube | (Amalgam) Compact | Fluorescent Lamp |
F26TBX/*/A/4 | CF26DT/E/IN/* | |
32W Triple Tube | (Amalgam) Compact | Fluorescent Lamp |
F32TBX/*/A/4P/EOL | CF32DT/E/IN/* | |
42W Triple Tube | (Amalgam) Compact | Fluorescent Lamp |
F42QBK/*/A/4P/EOL | CF42DT/E/IN/* |
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic,
120/277V, |
|
|
|
|
|
|
|
|
|
| ||||
4 Lamp |
| 26 Watt |
| 32Watt |
|
| 42Watt |
| ||||||
|
|
|
|
| ||||||||||
Voltage |
| 120V |
| 277V |
| 120V |
|
| 277V |
| 120V |
|
| 277V |
Total Input Watts |
| 112 |
| 110 |
| 138 |
|
| 134 |
| 182 |
|
| 180 |
Max. Line Current(amps) |
| 0.92 |
| 0.40 |
| 1.16 |
|
| 0.52 |
| 1.52 |
|
| 0.64 |
Power Factor |
| >0.95 |
| >0.95 |
| >0.98 |
|
| >0.98 |
| >0.98 |
|
| >0.98 |
Ballast Factor |
| 1.02 |
| 1.02 |
| 1.00 |
|
| 1.00 |
| 0.98 |
|
| 0.98 |
|
|
|
|
|
|
THD<10% Minimum Starting Temperature:
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus Suitable for Damp Locations.
Application Data
28 Inch Diameter |
|
|
|
30' x 30' x 10' Space |
|
|
|
Luminaire | Spacing: 10’ x 10’ |
| |
| Susp. Dist. 28” |
| |
4 Lamps | 26W | 32W | 42W |
| TTT | TTT | TTT |
Illum. (FC) Maint. | 26 | 33 | 45 |
Lum. Ratio | 15/1 | 15/1 | 14/1 |
Watts/Sq. Ft. | 1.10 | 1.36 | 1.86 |
Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.
CERTIFIED TEST REPORT NO. 4R28442A
COMPUTED BY LSI PROGRAM
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE
CAT. #4R28442APBU, 28” DIFFUSER
|
|
|
| CANDLEPOWER SUMMARY |
| ||||
|
|
| ANGLE MEAN CP LUMENS | ANGLE MEAN CP LUMENS | |||||
|
|
| 0 | 309 |
|
| 90 | 35 |
|
|
|
| 5 | 311 | 30 |
| 95 | 169 | 236 |
|
|
| 10 | 307 |
|
| 100 | 494 |
|
|
|
| 15 | 301 | 85 |
| 105 | 819 | 845 |
|
|
| 20 | 293 |
|
| 110 | 1064 |
|
|
|
| 25 | 283 | 131 |
| 115 | 1245 | 1234 |
|
|
| 30 | 269 |
|
| 120 | 1417 |
|
|
|
| 35 | 252 | 158 |
| 125 | 1585 | 1408 |
|
|
| 40 | 233 |
|
| 130 | 1692 |
|
|
|
| 45 | 215 | 166 |
| 135 | 1744 | 1349 |
|
|
| 50 | 195 |
|
| 140 | 1785 |
|
|
|
| 55 | 172 | 154 |
| 145 | 1825 | 1146 |
|
|
| 60 | 148 |
|
| 150 | 1863 |
|
|
|
| 65 | 124 | 123 |
| 155 | 1875 | 862 |
|
|
| 70 | 101 |
|
| 160 | 1838 |
|
|
|
| 75 | 76 | 82 |
| 165 | 1755 | 491 |
|
|
| 80 | 56 |
|
| 170 | 1587 |
|
|
|
| 85 | 37 | 45 |
| 175 | 1471 | 146 |
|
|
| 90 | 35 |
|
| 180 | 1584 |
|
|
|
|
|
|
|
| |||
|
|
|
| ZONAL LUMENS AND PERCENTAGES |
| ||||
|
|
| ZONE | LUMENS | % LAMP | %LUMINAIRE | |||
|
|
| |||||||
| DATE: MAR. 1, 2001 |
| 358 |
| 2.61 | 3.20 |
| ||
| PREPARED FOR: |
| 588 |
| 4.29 | 5.28 |
| ||
| LIGHTOLIER, FALL RIVER, MA |
| 1046 |
| 7.80 | 9.59 |
| ||
|
|
| 1373 |
| 10.73 | 11.20 |
| ||
|
|
|
|
| |||||
|
|
| 784 |
| 6.14 | 6.56 |
| ||
|
|
| 327 |
| 2.55 | 2.88 |
| ||
|
|
| 8040 |
| 62.81 | 88.80 |
| ||
|
|
| 9412 |
| 73.54 | 100.00 |
| ||
|
|
|
| ** EFFICIENCY = 73.5% ** |
|
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
| 80 |
|
| 70 |
|
| 50 |
|
| 30 |
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
1 | .58 .55 .53 | .50 .48 .46 | .37 .35 .34 | .24 .23 .22 | .12 .12 .12 | .08 | ||||||||||
2 | .50 .46 .43 | .44 .41 .38 | .32 .30 .28 | .21 .20 .19 | .11 .10 .10 | .07 | ||||||||||
3 | .44 .40 .36 | .39 .35 .32 | .28 .26 .24 | .18 .17 .16 | .09 .09 .08 | .06 | ||||||||||
4 | .39 .34 .30 | .34 .30 .27 | .25 .22 .20 | .16 .15 .13 | .08 .08 .07 | .05 | ||||||||||
5 | .34 .29 .26 | .30 .26 .23 | .22 .19 .17 | .15 .13 .12 | .08 .07 .06 | .04 | ||||||||||
6 | .31 .26 .22 | .27 .23 .19 | .20 .17 .15 | .13 .11 .10 | .07 .06 .05 | .04 | ||||||||||
7 | .27 .22 .19 | .24 .20 .17 | .18 .15 .13 | .12 .10 .09 | .06 .05 .05 | .03 | ||||||||||
8 | .25 .20 .16 | .22 .17 .15 | .16 .13 .11 | .11 .09 .07 | .06 .05 .04 | .03 | ||||||||||
9 | .22 .17 .14 | .20 .16 .13 | .14 .12 .10 | .10 .08 | .07 | .05 .04 .04 | .02 | |||||||||
10 | .20 .16 .13 | .18 .14 .11 | .13 .10 .08 | .09 .07 | .06 | .05 .04 .03 | .02 |
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Job Information | Type: |
|
|
Lightolier a Genlyte company |
| www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 Genlyte Group LLC • C0605