Carrier 38AN,BK specifications Installation, Start-Upan, For Use in High Wall Applications, Page

Models: 38AN,BK

1 30
Download 30 pages 50.49 Kb
Page 1
Image 1
Installation, Start-Up an

38AN,BK with 40QN009,012 Cooling Only/Heat Pump Systems

Installation, Start-Up an

Service Instructions

(For Use in High Wall Applications)

 

 

 

CONTENTS

 

 

 

 

 

 

Page
SAFETY CONSIDERATIONS

1

GENERAL

..................................

1,2

INSTALLATION
2-13
Step 1 - Complete Pre-lnstallation Checks

.... 2

UNPACK UNIT

 

 

INSPECT SHIPMENT

 

 

Step 2

-

Select Location

.....................

2

Step 3

-

Mount Mounting
Bracket on Wall .... 3

Step 4

-

Mount Outdoor
Section

9

Step 5

-

Connect Refrigerant Piping

I0

RIGHT REAR AND BOTTOM PIPING CONNECTIONS

RIGHT SIDE PIPING CONNECTIONS

LEFT SIDE PIPING CONNECTIONS

ALL TYPES PIPING CONNECTIONS

Step 6

-

Make Piping Connections

10

Step 7

-

Connect Condensate Drain Line ....

ll

Step 8

-

Make Electrical Connections

11

INDOOR SECTION WIRING

OUTDOOR SECTION WIRING

Step 9 - Install Fan Coil Unit Onto

 

Mounting Bracket

13

START-UP
14-17
40QN Control System

14

Wireless Remote Controllers

14

After Extended Shutdowns

14

 

Page

System Safeties and Interlocks

20

INDOOR FAN FAILURE

COMPRESSOR SHORT-CYCLING PROTECTION

INDOOR COIL FREEZE PROTECTION

INDOOR COIL HIGH-TEMPERATURE PROTECTION

TROUBLESHOOTING

20-27

START-UP CHECKLIST

CL-I, CL-2

SAFETY CONSIDERATIONS

Installing and servicing air-conditioning equipment can be hazardous due to system pressure and electrical compo- nents. Only trained and qualified service personnel should

install or service air-conditioning equipment.

Untrained personnel can perform basic maintenance func- tions such as cleaning coils and filters and replacing filters. All other operations should be performed by trained service personnel.

When working on air conditioning equipment, observe pre- cautions in the literature and on tags and labels attached to unit. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Before installation, read these in- structiens thoroughly. Consult local building codes and Na-

tional Electrical Code (NEC) for special installation requirements.

Seasonal Changeovers

14

To Turn the Unit On and Off

14

Adjusting
Airflow

14

Operating Mode Memory

14

Automatic
Operation (Auto) Mode

14

Operating
Fault Diagnosis

15

Microprocessor Control Operation

15

CLEANING AND MAINTENANCE
18-19
Lubrication

18

To Install or Replace Remote Controller

 

Batteries

18

To Set the Current Time

18

To Remove and Clean or Replace Air Filters .. 18

TO REMOVE AIR FILTERS

TO CLEAN OR REPLACE FILTERS

To Clean Indoor Unit Front Panel

19

To Clean
Indoor Coil

19

To Clean Outdoor Coil (Outdoor Unit)

19

To Clean Condensate Drains

19

SERVICE

...................................

20

Diagnostic

Codes

20

System Tests

20

• THERMISTOR

TESTS

 

• COMPRESSOR

FAILURE

 

• REVERSING VALVE FAILURE (38BK Only)

Electrical shock can cause personal injury or death. Be- fore installing or servicing system, be sure to turn off main power to system. There may be more than one dis- connect switch. Turn off indoor fan coil power as applicable.

GENERAL

The Carrier 40QNHOI 2 heat pump high wall fan coil unh (Fig. 1) comes with supplemental electric heat (40QNE009 heat pump fan coil unit does not have electric heat). If your

application requires heating, heat pump units must be used both outdoors and indoors. See Table 1 for recommended

system combinations.

The matched cooling and heat pump systems consist of an outdoor section (condensing unit or heat pump) and an in- door section (fan coil). The outdoor section (38AN or 38BK) is installed alongside the building structure. It can also be installed on a flat roof, deck, or on an apartment building balcony. The indoor section (40QNB009,012 or 40QNE009, 40QNH012) is mounted high on an interior wall that is con- venient for piping connection to the outdoor section. Two sizes are available: 9,000 and 12,000 Btuh cooling capaci- ties. See Fig. 1 for system components, Table 1 for system

ManuPacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1 4

PC 111

Catalog NO. 535-848

Printed in U.S.A.

Form 38A,BI40Q-1SI

Pg 1

5-99

Replaces: 53AN,BK-1SI

Page 1
Image 1
Carrier 38AN,BK specifications Installation, Start-Upan, For Use in High Wall Applications, Service Instructions, Contents