![Page 2 of 2](/images/new-backgrounds/40979/409793x1.webp)
Architectural Decorative 4R42
Page 2 of 2 | Pendalux Traditional 42" Diameter Body |
Features
1.Diffusing Reflector: White translucent acrylic, 3/16” thick.
2.Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3.Chassis: Steel 20 gauge,
4.Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia. fastened internally, no exposed hardware. Permits installation on ceilings with slope of up to 45°. Complies with California Code.
5.Rods: Reflector Bowl is suspended from a central point on three 3/16” steel rods.
6.Lampholder:
7.Flange Trim: Steel 20 gauge, Plated or Painted finish.
Lamping (by others)
Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.
General Electric | Osram/Sylvania | Philips |
26W Triple Tube | (Amalgam) Compact | Fluorescent Lamp |
F26TBX/*/A/4P | CF26DT/E/IN/* | |
32W Triple Tube | (Amalgam) Compact | Fluorescent Lamp |
F32TBX/*/A/4P | CF32DT/E/IN/* | |
42W Triple Tube | (Amalgam) Compact | Fluorescent Lamp |
F42QBK/*/A/4P | CF42DT/E/IN/* |
*Manufacturers’ color temperature designation.
Electrical
Ballast: Electronic,
120/277V, |
|
|
|
|
|
|
| |||
8 Lamp |
| 26 Watt |
| 32Watt |
| 42Watt |
| |||
|
|
|
| |||||||
Voltage |
| 120V | 277V |
| 120V |
| 277V | 120V |
| 277V |
Total Input Watts |
| 224 | 224 |
| 276 |
| 276 | 364 |
| 364 |
Max. Line Current(amps) |
| 1.84 | 0.8 |
| 2.32 |
| 1.04 | 3.04 |
| 1.28 |
Power Factor |
| >.98 | >.98 |
| >.98 |
| >.98 | >.98 |
| >.98 |
Ballast Factor |
| 1.02 | 1.02 |
| 1.00 |
| 1.00 | 0.98 |
| 0.98 |
THD <10% Minimum Starting Temperature:
Mounting
Mounts directly to 4” outlet box, using crossbar hanger, supplied.
Labels
cULus Suitable for Damp Locations.
Application Data
42 Inch Diameter
45' x 45' x 12' Space
Luminaire | Spacing: 15’ x 15’ |
| |
| Susp. Dist. 42” |
| |
8 Lamps | 26W | 32W | 42W |
| TTT | TTT | TTT |
Illum. (FC) Maint. | 25 | 35 | 45 |
Lum. Ratio | 11/1 | 11/1 | 12/1 |
Watts/ Sq. Ft. | .98 | 1.21 | 1.65 |
Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.
CERTIFIED TEST REPORT NO. 4K42842A
COMPUTED BY LSI PROGRAM
LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE CAT. #4K42442ASBU, 42” STANDARD DIFFUSER
|
|
| CANDLEPOWER SUMMARY |
| |||
|
| ANGLE | MEAN CP | LUMENS | ANGLE | MEAN CP | LUMENS |
|
| 0 | 551 |
| 90 | 152 |
|
|
| 5 | 581 | 55 | 95 | 823 | 877 |
|
| 10 | 573 |
| 100 | 1416 |
|
|
| 15 | 560 | 158 | 105 | 1801 | 1908 |
|
| 20 | 543 |
| 110 | 2197 |
|
|
| 25 | 521 | 241 | 115 | 2598 | 2545 |
|
| 30 | 497 |
| 120 | 2882 |
|
|
| 35 | 469 | 293 | 125 | 3112 | 2789 |
|
| 40 | 433 |
| 130 | 3329 |
|
|
| 45 | 393 | 303 | 135 | 3524 | 2713 |
|
| 50 | 349 |
| 140 | 3636 |
|
|
| 55 | 303 | 272 | 145 | 3788 | 2385 |
|
| 60 | 258 |
| 150 | 3978 |
|
|
| 65 | 215 | 214 | 155 | 4139 | 1961 |
|
| 70 | 173 |
| 160 | 3626 |
|
|
| 75 | 122 | 140 | 165 | 3415 | 993 |
|
| 80 | 93 |
| 170 | 3357 |
|
|
| 85 | 60 | 99 | 175 | 3633 | 359 |
|
| 90 | 152 |
| 180 | 4032 |
|
|
|
|
|
|
| ||
|
|
| ZONAL LUMENS AND PERCENTAGES |
| |||
|
|
|
|
|
|
|
|
DATE: MAR. 16, 2001 |
| ZONE | LUMENS% LAMP%LUMINAIRE |
| |||
PREPARED FOR: |
|
| |||||
LIGHTOLIER, FALL RIVER, MA | 493 | 1.93 | 2.72 |
| |||
| 811 | 3.17 | 4.46 |
| |||
|
| ||||||
| 1437 | 5.61 | 7.90 |
| |||
| 1929 | 7.53 | 10.60 |
| |||
| 1116 | 4.36 | 6.14 |
| |||
| 491 | 1.92 | 2.70 |
| |||
| 17843 | 64.70 | 98.00 |
| |||
| 19772 | 77.23 | 100.00 |
| |||
|
|
| ** | EFFICIENCY = 77.2% | ** |
|
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD %EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
| 80 |
|
| 70 |
|
| 50 |
|
| 30 |
|
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
1 | .58 .56 .53 | .51 .49 .46 | .38 .36 .35 | .25 .25 .24 | .14 .14 .13 | .08 | ||||||||||
2 | .51 .47 .41 | .44 .41 .38 | .33 .31 .28 | .22 .21 .20 | .12 .12 .11 | .07 | ||||||||||
3 | .49 .40 .36 | .39 .35 .32 | .29 .27 .24 | .20 .18 .17 | .11 .10 .10 | .06 | ||||||||||
4 | .39 .34 .31 | .35 .30 .27 | .26 .23 .21 | .16 .16 .14 | .10 .09 .08 | .05 | ||||||||||
5 | .34 .30 .26 | .31 .26 .23 | .23 .20 .18 | .16 .14 .12 | .09 .08 .07 | .04 | ||||||||||
6 | .31 .26 .22 | .27 .23 .20 | .20 .17 .15 | .14 .12 .11 | .08 .07 .06 | .04 | ||||||||||
7 | .28 .23 .19 | .24 .20 .17 | .18 .15 .13 | .13 .11 .09 | .07 .06 .05 | .03 | ||||||||||
8 | .25 .20 .17 | .22 .18 .15 | .17 .14 .11 | .11 .09 .08 | .06 .05 .05 | .03 | ||||||||||
9 | .23 .18 .14 | .20 .16 .13 | .15 .12 .10 | .10 .08 | .07 | .06 .05 .04 | .02 | |||||||||
10 | .20 .16 .13 | .18 .14 .11 | .14 .11 .09 | .09 .08 | .06 | .05 .04 .04 | .02 |
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
Job Information | Type: |
|
Lightolier a Genlyte company |
| www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2005 Genlyte Group LLC • B0605