SURGICAL PERIMETER LUMINAIRE SUS SERIES 432/632
Page 2 of 4 | 2'x4' RECESSED FLUORESCENT, ASYMMETRIC/SYMMETRIC ACRYLIC LENS |
| RFI SHIELDED, 4 OR 6 LAMP, T8 OR T12 |
PHOTOMETRY
G92056 | DATE: |
SUS2GFSMA432120O4 | |
4 F32T8 LAMPS | EACH RATED 2850 LUMENS |
REPORT NUMBER: | ITL38369 | DATE: |
|
|
| ||
PREPARED FOR: | LIGHTOLIER/GENLYTE |
|
|
|
|
|
|
CATALOG NUMBER: SUS2GFSMA632120O6 |
|
|
|
|
|
| |
LUMINAIRE: FABRICATED METAL HOUSING, WHITE PAINTED REFLECTOR, LINEAR |
|
| |||||
PRISMATIC PLASTIC ENCLOSURE WITH RFI GRID EMBEDDED |
|
|
| ||||
LAMPS: 6 F32T8 LAMPS EACH RATED 2850 LUMENS. |
|
|
|
|
|
| |
BALLASTS: |
|
| Black housing exterior |
|
| ||
MOUNTING: RECESSED | One piece housing has | for cooler ballast |
| Fully | |||
TOTAL INPUT WATTS: 231.0 AT 120.0 VOLTS | ribbed construction |
| operating temperature |
| |||
|
|
|
| gasketed | |||
LUMEN TO CANDELA RATION USED: 9.17 | for added strength |
|
|
| lens frame | ||
THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. |
|
|
|
| Hemmed | ||
|
|
|
|
|
|
| over |
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
|
|
|
| Symmetrical | Asymmetrical |
| for |
|
|
|
|
| safe | ||
|
|
|
| Distribution | Distribution |
| handling |
ORDERING INFORMATION
Explanation of Catalog Number. Example: SUS2GFSMA632120O6GLR
SU
S
2
FS
MA
32
|
|
| SURGICAL |
|
| |
|
|
| PERIMETER |
|
| |
|
|
| LUMINAIRE: |
|
| |
|
|
| Asymmetric/ |
|
| |
BLANK = Standard | BODY | |||||
Symmetric | ||||||
N = NYC Code | STYLE: | |||||
Distribution |
Lens Recessed | S = Static |
Fluorescent |
|
Troffer |
|
FIXTURE WIDTH
CEILING TYPE: G = Grid
Z spline and plaster frame
|
|
|
|
|
|
|
|
|
LENS FRAME: |
|
| LAMP QUANTITY: |
| ||||
FS = Flat |
|
| (By others) | LAMP/ | ||||
steel frame |
|
| 4 = | |||||
|
| FIXTURE | ||||||
(fully gasketed) |
|
| 6 = | |||||
|
| LENS/ |
|
| LENGTH: | |||
|
|
|
| 32=T8 | ||||
|
| SHIELDING |
|
| ||||
|
|
|
| (Nominal 48") | ||||
|
| TYPE: |
|
|
MA = Virgin Acrylic Asymmetric/ Symmetric Distribution (Standard)
VOLTAGE: |
|
| OPTIONS: |
120 or 277 |
| Add appropriate | |
|
|
| suffix to catalog |
|
|
| no, ie: (GLR) |
| BALLAST: |
| |
|
| <20THD | <10THD |
Lamp Elec. (T8) | SO* | HI* | |
Lamp Elec. (T8) | SO* | HI* | |
Lamp Elec. (T8) | O4* | H4* | |
Lamp Elec. (T8) | O6* | H6* | |
LOL Dimming T8 | PS | – | |
*Instant Start Standard |
|
|
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES
CONTINUOUS ROW INSTALLATION: For F type fixtures,
SEISMIC
FUSING: Internal
SUFFIX: GLR.
Internal
SUFFIX: GMF.
RADIO INTERFERENCE FILTER: (If one per ballast is required) 120 or 277 volt,
50 or 60 Hz. SUFFIX: RF. Not available on SUS632 (6 lamp) with
DRYWALL KIT: Order Catalog Number: FK92X4. (Request Folio
SPECIFICATIONS
MATERIALS: Chassis parts are
Specifications (continued)
FINISH: Chassis
LABELS: I.B.E.W./UL and
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902