Lytes pan® Track Lighting System 6450

Page 4 of 4 Suspension Beam System

4' Housing 8' Housing
4' Individual Track 8' Individual Track or
Joiner Track
"L"-Housing Splice Box
COMpONeNts
Layouts of ste ms and Cabels
Locate cables or ste ms uniformly along housings
not exceeding 8' spacin g. In a straight r un or open
pattern, locate fir st and last sup ports approx imately
1' from the ends.
Position stem for pow er feed at least 6" from
the end of the housing (or housing/splice box)
to which power is to be fed.
Position cable for powe r feed 6" to 10"f rom the
housing/splice box to which power is to be f ed.
The 10" distance may be increased by t he amount
the cable is shortene d on the job.
(1) 4’ Housing, (1) 4’lnd. Track
(1) 8’ Housing, (1) 8’ Joiner Track
Recommended Support : Stem or Wall Mount ing Kit
(4) 4’ Housings, (4) 4’ Ind, Tracks
(2) 8’ Housings, (2) 8’ Joiner Tracks
(4) “L” Housing/Splice Boxes
(4) Sets of 2 Aux. Elect. Connectors
Recommended Support : Stem or Cable
(2) 4’ Housings, (2) 4’ Ind. Tracks
(1) 8’ Housing, (1) 8’ Joiner Track
(1) “L” Housing/Splice Box
(1) Set of 2 Aux. Elect. Conne ctors
Recommended Support : Stem or Cable
NOte: Dimensions shown do no t include End Plate s.
sUspeNsION BeA M MOUNtIN G MAXIMUM LOA D*
Cables or Stems, spaced 8 Ft. apart 5 lb. Lytespots on 1 Ft . Spacing