![Calculite®](/images/new-backgrounds/41040/410403x1.webp)
| Calculite® | ® | Incandescent Lensed Downlight 7794QD | |
| Calculite |
| ||
| Incandescent |
|
| |
Page 2 of 2 | Lensed Downlight | 7 3/8” Aperture Horizontal Lamp Fresnel Lenslite |
INITIAL FOOTCANDLES
40
35
30
25
20
15
10
5
100 Watt
1750 Lumens Per Lamp
RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane) RCR = 10 (Rm. Width - Mtg. Ht. above work plane)
Room Surface Reflectances:
80% Ceiling; 50% Walls; 20% Floor
25 50 75 100 125 150 175 200 225 AREA PER FIXTURE IN SQUARE FEET
3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
Use quick calculator chart to determine spacing of luminaires for desired level of illumination.
Conversion Factors:
Spacing Ratio = 1.1
| Candlepower Summary | |||
90 | DEG | CP | ZONAL FLUX | |
| ||||
| 0 | 697 |
| |
150 | 5 | 686 | 65 | |
15 | 654 | 185 | ||
60 | ||||
25 | 634 | 294 | ||
| ||||
| 35 | 393 | 247 | |
300 | 45 | 140 | 108 | |
| 55 | 53.4 | 48 | |
| 65 | 26.3 | 26 | |
450 | 75 | 8.8 | 9 | |
| 85 | 2.6 | 3 | |
30 | 90 | 0 |
| |
|
|
| ||
600 | ZONE | LUMENS | % | |
| ||||
| 544 | 32.0 | ||
| 791 | 44.5 | ||
ETL, Inc. Report No. | 947 | 55.5 | ||
Date: | 985 | 58.0 | ||
Efficiency: 55.5% |
|
|
|
% Effective ceiling cavity reflectance
|
|
| 80 |
|
|
| 70 |
|
| 50 |
|
| 30 |
|
|
| 10 |
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| 50 | 30 | 10 |
|
|
| % Wall reflectance |
|
|
| 50 | 30 | 10 | 0 | ||||
|
|
| 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 |
| |||||||
| 1 | .64 | .62 | .61 | .62 | .61 | .60 | .60 | .59 | .58 | .58 | .57 | .56 |
| .56 | .55 | .54 | .53 | |
ratio | 2 | .60 | .57 | .55 | .59 | .56 | .54 | .57 | .355 | .53 | .55 | .53 | .52 |
| .53 | .52 | .51 | .50 | |
3 | .56 | .53 | .51 | .55 | .52 | .50 | .54 | .51 | .50 | .52 | .50 | .49 |
| .51 | .49 | .48 | .47 | ||
4 | .52 | .49 | .47 | .51 | .49 | .46 | .50 | .48 | .46 | .49 | .47 | .45 |
| .48 | .46 | .45 | .44 | ||
cavity |
| ||||||||||||||||||
5 | .49 | .46 | .43 | .49 | .45 | .43 | .48 | .45 | .43 | .47 | .44 | .42 |
| .46 | .44 | .42 | .41 | ||
6 | .46 | .43 | .40 | .46 | .43 | .40 | .45 | .42 | .40 | .45 | .42 | .40 |
| .43 | .41 | .39 | .39 | ||
Room |
| ||||||||||||||||||
7 | .43 | .40 | .38 | .43 | .40 | .38 | .42 | .39 | .37 | .42 | .39 | .37 |
| .41 | .39 | .37 | .36 | ||
8 | .41 | .37 | .35 | .40 | .37 | .35 | .40 | .37 | .35 | .39 | .36 | .34 |
| .39 | .36 | .34 | .34 | ||
|
| ||||||||||||||||||
| 9 | .38 | .35 | .32 | .38 | .35 | .32 | .37 | .34 | .32 | .37 | .34 | .32 |
| .36 | .34 | .32 | .31 | |
| 10 | .34 | .30 | .28 | .34 | .30 | .28 | .33 | .30 | .28 | .33 | .30 | .28 |
| .32 | .30 | .28 | .27 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20% Floor cavity reflectance Conversion Factor:
Job Information |
| Type: |
|
|
|
Lightolier a Genlyte Thomas Company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2003 Genlyte Thomas Group LLC (Lightolier Division) • B0303