7. POSITION KICK REFLECTORS

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:8021DW

A0399

Page 2 of 2

7. POSITION KICK REFLECTORS

KICK REFLECTOR

 

WALL

a.) After KICK REFLECTORS are properly assembled to

 

 

 

 

CLIPS, rotate RING to align KICK REFLECTORS

 

 

 

 

 

 

opposite walls to be illuminated.

 

 

 

For double wall washer see (Fig. 6).

 

FIG. 6

For corner wall washer see (Fig. 7).

 

 

 

8.

PUSH-IN

WALL

 

a.) For overlapping flange installation (Fig. 8), slip WHITE

 

 

 

TRIM RING over REFLECTOR. For Flangeless (Fig. 9)

KICK

 

and Self Flanged Trims, WHITE TRIM RING is not

 

REFLECTOR

 

required.

WALL

 

b.) Push REFLECTOR straight up to engage 3 RETAINING

 

 

 

SPRINGS.

FIG. 7

 

For double wall washer see (Fig. 10).

 

 

 

For corner wall washer see (Fig. 11).

WHITE TRIM

 

c.) Final adjustment can be achieved by rotating REFLEC-

RING

 

TOR. NOTE: To remove REFLECTOR squeeze RETAIN-

 

 

ING SPRINGS to disengage top portion of reflector.

 

9. CARE AND MAINTENANCE OF ALZAK REFLECTOR

 

 

REFLECTOR surfaces can be cleaned by the following

 

 

methods:

FIG. 8

FIG. 9

a.) Wipe off with a soft, clean, dry, lint-free cloth.

 

b.) Wipe off with a soft clean cloth dampened in mild

 

 

detergent solution. Rinse, the wipe dry with lint-free

 

 

cloth or paper towel.

 

 

c.) Wipe off with a clean cloth dampened with a solution

 

 

of wetting agent and water (such as 2 oz. per gallon

 

 

“Pluronic L62-LF” by Wyandotte Products). Then wipe

 

 

dry.

 

 

 

 