READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To assure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

INSTRUCTION SHEET NO.

IS:8292

0203

Page 1 of 2

INSTRUCTIONS FOR THE OPERATION AND ATTACHMENT OF POWERARCTO A LYTESPAN® TRACK SYSTEM. FOR USE WITH LYTESPAN TRACK SYSTEMS ONLY.

INSTRUCTIONS FOR ATTACHING ADAPTER TO SINGLE CIRCUIT LYTESPAN TRACK:

1.Position LEVER as shown in Fig. 1.

2.Align GROOVE in ADAPTER with BEAD on TRACK. See Fig. 1. (If GROOVE of ADAPTER is not placed over BEAD in TRACK, a potential hazard may result.)

3.Insert ADAPTER into TRACK.

4.Rotate LEVER 90° while pushing upward on ADAPTER, to make mechanical and electrical connection. See Fig. 2.

To remove or change fixture location on the TRACK, reverse procedure #4 above.

INSTRUCTIONS FOR CONVERTING POWERARC ATTACHMENT FITTING TO OPERATE ON 2 CIRCUIT LYTESPAN TRACK:

NOTE: To insure proper operation of POWERARC on Two Circuit Lytespan Track, the BLACK SPACER (provided) must be used at all times on the plug assembly. The BLACK SPACER is not used when operating POWERARC on Single Circuit Track.

LOWER CIRCUIT, Fig. 3 & 6:

Illustrates contacts in low position with spacer in place for lower circuit.

UPPER CIRCUIT, Fig. 4, 5, & 6:

To convert attachment fitting for upper circuit, raise BRASS CONTACT to high position (as indicated by dotted line) by pulling CONTACT as high as stop permits and slipping on BLACK SPACER as shown in Fig. 4 & 5.

Do not try to move stationary silver contact.

AIMING ADJUSTMENTS:

CAUTION: ALLOW TIME FOR FIXTURE TO COOL BEFORE MAKING ANY ADJUSTMENTS!

Rotate fixture both HORIZONTALLY and VERTICALLY to the desired position. Fixture has horizontal and vertical rotation stops (DO NOT FORCE FIXTURE PAST STOPS. DOING SO MAY CAUSE AN ELECTRICAL HAZARD) See FIG. 7. For precise VERTICAL rotation, rotate HEAD of fixture and line up desired angle on the AIMING ANGLE INDICATOR with the INDICATOR TAB (See FIG. 8).

TRACK

BEAD

 

 

 

 

 

 

 

LEVER

GROOVE

 

 

 

 

 

 

 

ADAPTER

 

 

 

 

 

 

 

ADAPTER

FIG. 1

BLACK

FIG. 2

LEVER IN

 

MOVABLE

ENERGIZED POSITION

SPACER

 

 

BRASS

 

 

 

 

CONTACT

 

 

 

 

 

PLUG

MOVABLE

 

STATIONARY

 

ASSEMBLY

BRASS

 

CONTACT

 

ADAPTER

CONTACT

 

(Common)

 

 

 

 

PLUG

 

 

 

 

ASSEMBLY

FIG. 3

 

BLACK

 

ADAPTER

 

 

 

 

 

SPACER

 

 

MOVABLE

BLACK

 

 

 

BRASS

 

 

 

CONTACT

SPACER

 

FIG. 4

 

 

 

 

 

PLUG

 

ASSEMBLY

UPPER

ADAPTER

 

CIRCUIT

 

Common

FIG. 5

LOWER

CIRCUIT

 

HORIZONTAL

FIG. 6

ROTATION

 

 

FIG. 7

INDICATOR

AIMING

VERTICAL

TAB

ANGLE

 

 

INDICATOR

ROTATION

 

 

 

 

 

FIG. 8

HEAD

®

LIGHTOLIER a GENLYTE company.

631 Airport Road, Fall River, MA 02720

Page 1
Image 1
Lightolier instruction sheet IS8292, Lightolier a Genlyte company, Airport Road, Fall River, MA, Instruction Sheet no

8292 specifications

The Lightolier 8292 is a sophisticated lighting fixture designed for both commercial and residential applications, blending form and function seamlessly. This model showcases a sleek, modern aesthetic that allows it to fit into a variety of architectural styles. Its minimalist design accentuates the light quality, directing attention to the illuminated spaces rather than the fixture itself.

One of the most notable features of the Lightolier 8292 is its advanced LED technology, which provides exceptional energy efficiency compared to traditional incandescent or fluorescent bulbs. With a lifespan of up to 50,000 hours, the LED components significantly reduce the frequency of replacements, which not only saves on maintenance costs but also minimizes environmental impact. The high luminous efficacy ensures that the light output is maximized while consuming less power, making it an ideal choice for sustainable building practices.

The fixture offers versatile light distribution options, allowing users to choose the appropriate beam angle for their specific needs. Whether you require a narrow spotlight for accenting artwork or a wider beam for general illumination, the Lightolier 8292 can be adapted accordingly. Additionally, its dimmable feature provides further control over the brightness levels, enabling users to create the desired ambiance for various settings, from cozy residential spaces to dynamic commercial environments.

The construction of the Lightolier 8292 is robust yet lightweight, utilizing high-quality materials that ensure durability while also making installation straightforward. It can be mounted in various configurations, including on ceilings or walls, giving users flexibility in their lighting layout. The fixture is also compatible with a range of smart home systems, providing users with the ability to integrate lighting control into their existing automated setups.

Moreover, the design of the Lightolier 8292 emphasizes thermal management, ensuring that the fixture operates efficiently without overheating. This contributes to the overall longevity of the product, as effective heat dissipation reduces the strain on the internal components.

In summary, the Lightolier 8292 is an exceptional lighting solution characterized by its energy-efficient LED technology, versatile light distribution, and smart integration capabilities. Its durability, modern design, and adaptability make it a popular choice among architects, designers, and homeowners alike, solidifying its place as a leader in contemporary lighting solutions.