Lighting Systems A-4
1BHFPG |
6
2
4
1
3
(24.29cm)
3-5/8” (9.21cm)
Module Ordering Information
|
| NOT TO SCALE |
| ||
|
|
Family |
| Series |
A |
| 1 |
Complete ordering instructions below.
Track
B
A = Track
B = No Track
Length
4=
8 =
12 =
Shielding
B
A = No Shield
B = Solid Shield
C = Perf Shield
D = Lens Shield
Lamps
28 = 28w
54 = 54w
Finish
WH = White AL = Aluminum
Options
EM = Emergency
D1 = Dimming 120v
D2 = Dimming 277v
X5 = 5 Through Wires
Features
1.Housing: Extruded aluminum housing in lengths of 4’ (121.92cm), 8’ (243.84cm) and 12’ (365.76cm). There are no exposed fasteners. The end caps are
2.Lens: Extruded clear acrylic linear prismatic lens.
3.Reflector:
4.Lamping: One T5 28W or 54W lamp per
5.Alignment Mechanism: The housing and the end cap each have a draw tight mechanism that creates a hairline joint along and at the ends of the run. To operate the mechanism, the installer tightens two screws.
6.Shielding:
Labels
UL, cUL and I.B.E.W.
Finish
Powder coated baked white or silver enamel.
Custom colors available, consult factory.
Mountings
All mounting is on 48” (121.92cm), 96” (243.84cm) and 144” (365.76cm) centers. Cable Suspension (not shown) 4 1/2" (11.43cm) diameter flat canopy finished white enamel, 1/16" (0.16cm) diameter stainless steel aircraft cable adjustable up to 36" (91.44cm) and adjustable cable gripper. Cable mounting at the ends of a run is not available when track is being used. Installing stems at the ends of the run will prevent the fixture from hanging off center caused by the weight of the track fixture. Cable suspension can be used in the center of runs that have track installed. Consult factory for other options.
Stem Mounting (not shown) - 4 1/2" (11.43cm) diameter flat canopy, 1/4"
(0.64cm) IP (1/2” (1.27cm) OD) stem. The stem can accommodate up to
Electrical
Ballast is <10% THD, 1.0 ballast factor, program start.
Dimming: 120/277 VAC 1% dimming level, 4 or 5 wire feed required.
Emergency Battery Pack: 28 watt: 520 lumens @ 90 minutes, 54 watt: 700 lumens @ 90 minutes.
Ordering Instructions
Individual Fixtures:
1.Order number of MODULES required.
2.Order one POWER FEED END SET per MODULE.
Continuous Rows:
1.Determine run length.
2.Order the appropriate number of MODULES for the complete run.
3.Order one POWER FEED END SET per run.
4.Order one INTERMEDIATE SUSPENSION per MODULE minus one per run.
5.For runs that exceed amperage limits, order the appropriate number of
INTERMEDIATE POWER FEEDS.
Job Information | Type: |
Job Name:
Cat. No.:
Lamp(s):
Notes:
"JSQPSU3PBE'BMM3JWFS."t t'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt $