Calculite® HID A-E
Page 1 of 1 | Auxiliary Lighting Systems For Temporary H.I.D. Lamp Outage |
Auxiliary Lighting for Recessed HID Luminaires and Cylinders (A)
H.I.D. lamps require a
To provide a minimum level of illumination, a
The
Note: The auxiliary is not emergency lighting and will only operate when there is power to the luminaire. The AUX system is available for magnetic ballast either 120V or 277V branch circuits with a ballast tap supplying 120V to the tungsten- halogen lamp. 120V electronic ballast can be operated with 120V branch circuit. For 277V, electronic, consult factory.
To specify: add suffix “A” to Catalog Number for Recessed H.I.D. Fixture. See fixture specification sheets for compatibility.
Emergency Lighting for Recessed HID Luminaires (E)
A
To specify: add suffix “E” to Catalog Number for Recessed H.I.D. Fixture. See fixture specification sheets for compatibility.
Maximum Tungsten-Halogen Lamp Wattage
HID Lamp | |
| |
75W | |
150W T6 | 75W* |
100W | |
175W | 150W |
150W |
*Applicable for any reflector trim with “CL” finish.
Mode of Operation
Initial Start:
H.I.D. lamp and tungsten halogen lamp both energized. H.I.D. lamp starts warming up;
Partial
H.I.D. lamp reaches approximately 60% light output; tungsten- halogen lamp switched off.
Full
H.I.D. lamps at 100% light output.
“Hot” Restart:
H.I.D. lamp and
Job Information | Type: |
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508)
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • B0704